_ Switching and checking

in the weighing mode

Set points (limit values) can only be set in weighing and counting mode. 3 memories for limit values are available for each connected scale: Entry must be additive, i.e. the weight of first limit value should be added to the second. Limit values affect the net weight.

Loading memory

Enter the value for the set point with the numeric keyboard.

Press the ”Ld” command key, followed by the number of the memory.

Confirm your entry by pressing the function key.

Memories 2 and 3 are entered and displayed in the same way.

Recalling of stored values

Press the ”i” command key and the number of the memory containing the value you require.

Confirm your entry with the ” ” function key.

Weighing with limit values

Tare the container

Place the items to be weighed on the scale.

The relevant symbol goes out when the appropriate set point/limit value reached.

Clearing memory

Press the ”CI” command key.

Now enter the number of the memory you wish to delete.

Confirm your entry with the appropriate function key. Simply overwriting the memory as described under ”Loading the memory” also deletes the current value.

Control weighing

Enter the upper and lower tolerance weights as in ”Loading memory” in S1 and S2. Place the items to be weighed on the scales. The current weight value and the tendency symbol appear on the main display:

Weight is less than set value ”S1”

Weight is within the tolerance ”S1-S2”

Weight is greater than set value ”S2”

9