b) Changing or overwriting a fixed tare value memory
Press the Print key and the F key simultaneously; Setting mode appears in the display.
The arrow points to "Program Settings". Confirm by pressing the Print key.
The arrow points to "General". Confirm by pressing the Print key.
Scroll to "Fixed tare value" with the Tare key and accept by pressing the Print key.
The last selected fixed tare value memory is displayed.
Select the tare memory you wish to change by pressing the F key or the Tare key, or enter the
memory location number and confirm by pressing the Print key.
Press the Print key; the input box to enter the description of the tare memory is displayed.
Change the description in the alphanumeric keypad and confirm by pressing the Print key.
The arrow points to "Tare value" .
Press the Print key; the input box for the tare value is displayed.
Change the tare value in the numeric keypad and confirm by pressing the Print key.
Return to tare memory selection by pressing the Zeroing key.
If you want to change other tare memories, press the F key of the Tare key to select the next
memory location to be changed and repeat the procedure as described above.
To return to Weighing mode, press the Zeroing key and then the ORG key.
c) Calling up the list of fixed tare value memories for taring
The tare value from the fixed tare value memory can be activated with the scale unloaded
(i.e. before the weighing operation) or with the scale loaded (during a weighing operation).
Aweight value 0.000kg appears in the display panel.
Press the Print key and the Tare key simultaneously.
The fixed tare value memory last used appears in the display.
Scroll to the required fixed tare value memory by pressing the F key or Tare key or
enter the memory location number and confirm by pressing the Print key.
Activate the fixed tare value by pressing the Print key.
The display shows the gross value less the tare value (net).
Further tare values from the memory are activated by repeating the procedure described
above.
d) Clearing an existing fixed value
Press the Print key and the F key simultaneously; Setting mode appears in the display.
The arrow points to "Program Settings". Confirm by pressing the Print key.
The arrow points to "General". Confirm by pressing the Print key.
Scroll to "Fixed tare value" by pressing the Tare key and accept with the Print key.
The last selected fixed tare value memory is displayed.
Scroll to the required fixed tare value memory by pressing the F key or Tare key or
enter the memory location number and confirm by pressing the Print key.
Clear the displayed fixed tare value memory by pressing the C key.
The gap in the consecutive number scheme is closed. The following fixed tare value memories
are given a number reduced by 1.