Soleus Air KC-30H / KC-35H Before Calling Service, When Service Is Required, Any Questions?

Models: KC-30H / KC-35H

1 22
Download 22 pages 16.18 Kb
Page 17
Image 17
Before Calling Service

Before Calling Service

To reduce the risk of electric shock, personal injury, or death, turn the fan control to the off position and remove the unit plug from the wall outlet before doing any inspection or maintenance work.

The following is a list of problems that are sometimes encountered when using a room air conditioner. Possible cause and suggested remedies are given for each problem.

If the problem cannot be fixed using the suggested remedies, see WHEN SERVICE IS REQUIRED section.

PROBLEM

POSSIBLE CAUSE

SUGGESTED REMEDY

UNIT WILL NOT RUN

No power to unit

Push reset button on power cord.

 

 

Set Fan Control to position other than OFF.

 

 

Make sure plug is firmly seated in outlet.

 

 

Check for blown fuses, tripped circuit breakers.

 

 

 

LITTLE OR NO COOLING

Fresh air/exhaust damper open

Set vent to CLOSED.

LITTLE OR NO HEATING

Obstructed indoor or outdoor airflow

Remove obstruction from indoor grille or outdoor louvers.

(fan and compressor run)

Dirty air filters

Dirty air filter. Clean or replace, as needed.

 

Unit undersized for application

Check with dealer to determine proper capacity unit for application.

 

 

 

LITTLE OR NO COOLING

Temperature Control not set properly

For cooling, turn Temperature Control to cooler setting.

LITTLE OR NO HEATING

 

 

(only fan runs)

 

For heating, turn Temperature Control to warmer setting.

 

 

 

NOISY UNIT

Loose front on mounting assembly

Tighten any loose parts.

 

Weak building construction

Provide additional support for unit.

 

Water hitting fan blade

Normal in high humidity. Stop noise by removing drain plug or adding

 

 

condensate drain cup.

 

Unit oversized for application:

Check with dealer to determine proper capacity unit for application.

 

compressor cycles on and off frequently

 

 

 

 

MOUNTING SUPPORT NOT

Storm window frame installed in window

Some models require removal of storm window frame before

INSTALLED

 

installation.

FROST ON INDOOR COIL

Dirty air filter

Clean air filter by vacuuming or washing with water and mild soap.

 

Normal for low outdoor temperatures

Turning Temperature Control to warmer setting reduces occurrence and

 

 

duration of frost.

 

 

 

FROST ON OUTDOOR COIL

Normal for outdoor temperatures at or

Call for service only if unit does not heat room and you have

checked all problems and remedies listed under LITTLE OR NO

(heat pump models only)

below 45°F

HEATING.

 

 

 

 

 

ODORS IN COOLING

Mold, mildew, or algae formation on wet

To reduce algae growth, use algaecide tablet in base pan; remove

 

Surfaces

drain plug; add condensate drain cup and hose. Thoroughly clean unit.

ODORS IN HEATING

Normal for first time electric heater is

Caused by dust accumulation during unused months.

used each season

Odor dissipates quickly with heater use.

 

 

 

 

When Service Is Required

Your room air conditioner dealer can give you the name of your nearest Authorized Service Center. Help them give you prompt service by providing:

An accurate description of problem.

Complete model, serial, and manufacturing (P) numbers from serial plate.

Proof of purchase (sales receipt) upon request.

Repair by unauthorized servicer that results in subsequent failure of unit voids warranty. Warranty details are contained in warranty certificate enclosed with unit.

Keep accurate records of service calls, including what was done, servicer’s name, and date of service.

Any Questions?

Most questions can be answered by your local Soleus Air brand dealer. If you have other matters that cannot be resolved locally, or you need additional information regarding other heating and cooling products offered by us - please call:

CONSUMER INFORMATION LINE

1-888-8-SOLEUS

(Technical Support and Warranty Service)

15

Page 17
Image 17
Soleus Air KC-30H / KC-35H installation manual Before Calling Service, When Service Is Required, Any Questions?