15 9/16"
22 13/16"
Electrical outlet must be located within
Dimensions of Finished Opening
MasonryConstruction
See CAUTION under General Instructions. In masonry walls, cut or build a finished opening 15
Placement of Outer Case in Opening
Place outer case in opening, flush against one side of opening. Use carpenter’s level and ensure case is level from side to side and has a
When case is properly positioned in opening, use wood shims to fill any gaps between case and finished opening, especially in area where case will be secured to opening.
Take care not to warp or distort case when installing shims. For condensate drainage, install drainage cup in drain hole on baseplate of case.
Outercase must project a minimum ¾" beyond inside wall
or molding to attach front frame
Lintel and flashing (if required)
Brick Veneer or Frame Wall Construction.
See CAUTION under General Instructions. Cut or build rough opening large enough to allow a framed, finished opening 15
nstall case 3/8"
5 1/2" |
Front of outer case |
to side air louvers |
Caulk all sides
Optional molding (not provided)
Framing | 15 9/16" |
lumber |
|
22 13/16"
Installed Case
(brick veneer or frame wall construction
shown)
Framed/Finished Opening
(brick veneer or frame wall construction)