Note: The shape of your mounting plate may be different from the one above, but installation method is simllar.

Installation instructions

Select the installation locations

Indoor unit installation location:

Locate indoor unit so that there is not obstruction near the supply air or return air outlets.

The wall that the indoor unit hangs on must be free from internal obstructions to facilitate a clear hole for the refrigeration lines and condensate line to go through.

Proper clearances must be maintained to ceilings and walls per instructions on page 16.

Easy access must be maintained for removal of the air filter.

Indoor unit and remote control must be at least 3 feet from televisions, radios, etc.

Indoor unit and remote control must be kept out of direct sunlight and/or fluorescent lighting.

The wall that the indoor unit hangs on must strong enough to bear the weight of the

unit to ensure quieter operation.

Outdoor unit installation location:

Outdoor unit location must be well ventilated. Avoid installing where any type of flammable gas could leak.

Proper clearances must be maintained per instructions on page 16.

The maximum length for refrigeration lines is 49 ft. For refrigeraton lines exceeding 23ft. an additional .75 pounds must be added per 3.5 feet.

The Maximum height between indoor and outdoor units in 25ft. If the outdoor unit is located above the indoor unit more than 4 ft., a suction line oil trap must be installed.

The outdoor unit must not be located in environments that have high contents of acidic substances, vulcanized gasses, or high salt contents in the air.

The outdoor unit must not be located near locations where dirt, mud, or debris can be caked onto the outdoor coil or unit.

The foundation that the outdoor unit sits on must be solid and sound so as to decrease noise vibration.

No obstructions should be placed around the outdoor unit.

Indoor unit installation

1. Installing the mounting plate

Hold mounting plate on the wall where unit will be located. Using a level or plumb line, ensure that the plate is level. Once the plate is level, mark holes that will be used to hold plate on the wall.

Remove plate and drill marked hole at a depth of 1.75 inches.

Insert the screw plugs into the holes and affix the mounting plate using the tapping screws.

Once mounting plate is securely fastened to the wall, then locate an area on the wall for the access hole for the refrigeration line/condensate line/wiring bundle.

2. Access hole for refrigeration lines/condensate drain line/wiring bundle.

These directions must be followed at least for the condensate drain line. There must be rear access for the condensate drain line to drain properly from the unit.

Decide on a location for the access hole according to the location of the unit.

Drill an approximately 2.5 inch hole, making sure that there is a tilt downward of a 1/4 inch. This will ensure that proper drainage is maintained for the condedsate drain line. (If you are not using rear access for the refrigeration lines and wiring, hole will does not need to be as large.)

It is recommended that a wall sleeve of some sort (i.e. PVC pipe) be used to keep the hole neat and tidy.

- 17 -

Page 19
Image 19
Soleus Air KFR/KFS Series manual Indoor unit installation location, Outdoor unit installation location

KFR/KFS Series specifications

Soleus Air has established itself as a reliable name in the heating, ventilation, and air conditioning (HVAC) industry, particularly with its KFR/KFS Series. This series of split-type air conditioners is designed to provide efficient cooling and heating solutions for both residential and commercial spaces. One of the standout features of the KFR/KFS Series is its energy efficiency, enabling users to enjoy comfortable indoor climates while minimizing energy consumption.

The KFR/KFS Series is equipped with advanced inverter technology. This technology allows the units to adjust their cooling and heating output based on the ambient temperature and humidity levels, providing a more stable and comfortable environment. Unlike traditional systems that continuously cycle on and off, inverter systems can operate at varying speeds, leading to significant energy savings and quieter operation.

Another important characteristic of the KFR/KFS Series is its multi-functional capabilities. These units not only provide cooling during the hot summer months but can also heat spaces during the colder winter months. This dual functionality makes them a versatile solution for year-round climate control. Additionally, these units often come with various modes, such as dehumidification and fan-only modes, which further enhance their adaptability to different environmental conditions.

The series is designed with user convenience in mind. Many models include easy-to-read remote controls, programmable timers, and a variety of settings that allow users to customize their comfort levels. The option for Wi-Fi connectivity in some models also enables users to control their air conditioner through smartphone applications, adding a layer of convenience and smart home integration.

On the design front, the KFR/KFS Series boasts a sleek and modern aesthetic that can easily blend into various interior styles. The units are compact, allowing for flexibility in installation while ensuring they do not take up valuable living space. Their whisper-quiet operation ensures that they maintain a serene environment, making them an ideal choice for bedrooms, offices, and other quiet spaces.

Durability is another hallmark of the KFR/KFS Series. Built with high-quality materials, these air conditioners are designed to withstand various environmental conditions while delivering reliable performance. The filters are easy to access and clean, promoting better air quality and reducing the need for frequent replacements.

Overall, the Soleus Air KFR/KFS Series stands out in its class for its energy efficiency, advanced technology, user-friendly features, and reliable performance, making it a top choice for anyone seeking a robust and versatile air conditioning solution.