Soleus Air KFR/KFS Series manual Troubleshooting, RUN light blinks, Defect, What to check

Models: KFR/KFS Series

1 32
Download 32 pages 44.1 Kb
Page 32
Image 32
Troubleshooting

Troubleshooting

RUN light blinks

Defect

What to check

 

 

 

1 time

Abnormality of room temperature

Open circuit or short circuit of room

temperature sensor.

 

sensor.

 

 

Incorrect connection of the sensor.

 

 

 

 

 

2 times

Abnormality of defrost sensor.

Open circuit or short circuit of defrost

sensor.

 

 

Incorrect connection of the sensor.

 

 

 

3 times

Abnormality of indoor fan motor.

Indoor fan motor is defective.

 

 

Bad connection to motor.

 

 

 

 

 

Compressor is defective.

4 times

Abnormality of outdoor unit.

Refrigerant is low.

 

 

 

 

Capacitor is defective.

 

 

 

Continuous

No defect-unit in defrost mode.

 

blink

 

 

 

 

 

- 30 -

Page 32
Image 32
Soleus Air KFR/KFS Series manual Troubleshooting, RUN light blinks, Defect, What to check