!USE COPPER WIRES ONLY FOR POWER SUPPLY.

!WARNING

!USE COPPER WIRES ONLY FOR POWER SUPPLY.

!WARNING:RISK OF ELECTRIC SHOCK CAN CAUSE INJURY OR DEATH. DISCONNECT ALL ELECTRIC POWER SUPPLIES BEFORE SERVICING.

!DURING CONNECTION OF THE REFRIGERATION TUBES, IF EXCESSIVE TORQUE IS IMPOSED ON FLARE NUTS, SERVICE VALVE ON DISCHARGE LINE MAY BE DAMAGED. WHEN TIGHTENING FLARE NUTS OR NARROW PIPE, TORQUE SHOULD BE ADJUSTED BETWEEN 13.7~18.6N.M (140~190GF.CM).

!DO NOT PUT INDOOR UNIT IN LOCATIONS WHERE IT MAY GET WET.

!ELECTRICAL INSTALLATION MUST BE IN ACCORDANCE WITH LOCAL AND NATIONAL ELECTRICAL CODES.

!THEINSTALLATIONOFTHESEUNITSREQUIRESQUALIFIEDPERSONNEL.

!CERTIFIED(APPROVED) POWER SUPPLY CONDUCTORS MUST BE USED.

!AN INDEPENDENT BRANCH CIRCUIT BREAKER MUST BE USED.

!MAXIMUM INTER CONNECTING WIRE LENGTH SHOULD NOT EXCEED 11.3M (37FT.)

!REFRIGERATING PIPE LENGTH MUST BE LIMITED BETWEEN 4~10M ( 13FT~33FT.) IF THE LENGTH EXCEEDS 7.62M(25FT.), THE COOLING (OR HEATING) CAPACITY MAY BECOME IMPAIRED.

!DIFFERENCE IN HEIGHT BETWEEN INDOOR AND OUTDOOR UNIT SHOULD NOT EXCEED 7M(26 FT.).