Sony CDP-CE575 service manual Ver

Models: CDP-CE575

1 48
Download 48 pages 62.47 Kb
Page 2
Image 2
CDP-CE575

CDP-CE575

Ver 1.1 2001.07

 

TABLE OF CONTENTS

 

1.

SERVICEING NOTES

3

2.

GENERAL

6

3.DISASSEMBLY

3-1.

Disassembly Flow

8

3-2.

Case (409538)

9

3-3.

Front Panel Section

9

3-4. CD Mechanism Deck (CDM59-5BD27)

10

3-5.

MAIN Board

10

3-6.

Base Unit (BU-5BD27)

11

3-7.

Table Assy

11

3-8.

Sensor Board

12

3-9.

Loading Motor Board

12

4.

ASSEMBLY

13

5.

TEST MODE

14

6.

ELECTRICAL ADJUSTMENTS

18

7.DIAGRAMS

7-1. Note for Printed Wiring Boards and

 

 

Schematic Diagrams

21

7-2.

Printed Wiring Board

– BD Section

22

7-3.

Schematic Diagram – BD Section

23

7-4. Printed Wiring Boards

 

 

 

– MOTOR/SENSOR Section

24

7-5.

Schematic Diagram – MOTOR/SENSOR Section – ....

25

7-6.

Schematic Diagram – MAIN Section (1/2)

26

7-7.

Schematic Diagram – MAIN Section (2/2)

27

7-8.

Printed Wiring Boards

– MAIN Section

28

7-9.

Printed Wiring Boards

– DISPLAY Section

30

7-10. Schematic Diagram – DISPLAY Section

31

7-11. IC Pin Function Description

32

8.EXPLODED VIEWS

8-1.

Case Section

36

8-2.

Front Panel Section

37

8-3.

Chassis Section

38

8-4. CD Mechanism Deck Section-1

 

 

(CDM59-5BD27)

39

8-5. CD Mechanism Deck Section-2

 

 

(CDM59-5BD27)

40

8-6. Base Unit Section (BU-5BD27)

41

9.

ELECTRICAL PARTS LIST

42

SAFETY CHECK-OUT

After correcting the original service problem, perform the follow- ing safety check before releasing the set to the customer:

Check the antenna terminals, metal trim, “metallized” knobs, screws, and all other exposed metal parts for AC leakage.

Check leakage as described below.

LEAKAGE TEST

The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microamperes.). Leakage current can be measured by any one of three methods.

1.A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturers’ instructions to use these instruments.

2.A battery-operated AC milliammeter. The Data Precision 245 digital multimeter is suitable for this job.

3.Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The “limit” indica- tion is 0.75 V, so analog meters must have an accurate low- voltage scale. The Simpson 250 and Sanwa SH-63Trd are ex- amples of a passive VOM that is suitable. Nearly all battery operated digital multimeters that have a 2 V AC range are suit- able. (See Fig. A)

To Exposed Metal

Parts on Set

0.15 F

 

 

 

1.5 k

AC

 

 

 

voltmeter

 

 

 

 

 

(0.75 V)

 

 

 

 

 

 

Earth Ground

Fig. A. Using an AC voltmeter to check AC leakage.

SAFETY-RELATED COMPONENT WARNING!!

COMPONENTS IDENTIFIED BY MARK 0 OR DOTTED LINE WITH MARK 0 ON THE SCHEMATIC DIAGRAMS

AND IN THE PARTS LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUB- LISHED BY SONY.

ATTENTION AU COMPOSANT AYANT RAPPORT

À LA SÉCURITÉ!

LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE 0

SUR LES DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE REMPLACER CES COM- POSANTS QUE PAR DES PIÈCES SONY DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU DANS LES SUPPLÉMENTS PUBLIÉS PAR SONY.

2

Page 2
Image 2
Sony CDP-CE575 service manual Ver