•MAIN BOARD IC301 CXP84648-085Q (SYSTEM CONTROLLER)
Pin No. |
| Pin Name | I/O |
| Description | ||
|
|
|
|
|
|
| |
1 to 4 |
| A3 to A6 | O | Address signal output to the static RAM (IC302) |
| ||
5 |
| GND | — | Ground terminal |
|
| |
|
|
|
|
|
|
| |
6 to 13 |
| D0 to D7 | I/O |
| |||
|
|
|
|
|
| ||
14 |
| CE | O | Chip select signal output to the static RAM (IC302) | |||
|
|
|
|
|
|
|
|
15 to 18 |
| NC | — | Not used (open) |
|
| |
|
|
|
|
|
| ||
19 |
| WE | O | Write enable signal output to the static RAM (IC302) | |||
|
|
|
|
|
| ||
20 | LOAD OUT | O | Loading motor (M10) drive signal output to the BA6780 (IC11) | ||||
|
|
|
|
|
| ||
21 |
| LOAD IN | O | Loading motor (M10) drive signal output to the BA6780 (IC11) | |||
|
|
|
|
|
| ||
22 |
| FL CLK | O | Serial data transfer clock signal output to the FL driver (IC801) | |||
|
|
|
|
|
|
| |
23 |
| FL DATA | O | Serial data output to the FL driver (IC801) |
| ||
|
|
|
|
|
|
| |
24 |
| FL RST | O | Reset signal output to the FL driver (IC801) |
| ||
|
|
|
|
|
|
| |
25 to 27 | A13, A14, A7 | O | Address signal output to the static RAM (IC302) |
| |||
|
|
|
|
|
|
| |
28 |
| DSENS | I | Detect signal input from the disc sensor (D11) |
| ||
|
|
|
|
|
|
|
|
29 |
| NC | — | Not used (open) |
|
| |
|
|
|
|
|
| ||
30 |
| RST | I | System reset signal input from the reset signal generator (IC603) “L”: reset | |||
| For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H” | ||||||
|
|
|
|
| |||
|
|
|
|
|
|
| |
31 |
| EXTAL | I | Main system clock input terminal (10 MHz) |
| ||
|
|
|
|
|
| ||
32 |
| XTAL | O | Main system clock output terminal (10 MHz) |
| ||
|
|
|
|
|
|
| |
33 |
| VSS | — | Ground terminal |
|
| |
|
|
|
|
|
| ||
34 |
| TX | O | Sub system clock output terminal | Not used (open) | ||
|
|
|
|
|
| ||
35 |
| TEX | I | Sub system clock input terminal | Not used (fixed at “L”) | ||
|
|
|
|
|
| ||
36 |
| AVSS | — | Ground terminal (for A/D converter) |
| ||
|
|
|
|
|
| ||
37 |
| AVREF | I | Reference voltage input terminal (+5V) |
| ||
|
|
|
|
|
|
| |
38 |
| NC | — | Not used (open) |
|
| |
|
|
|
|
|
| ||
39 |
| VERSION | I | Model Destination setting terminal |
| ||
|
|
|
|
|
|
| |
40 |
| ADJ | I | Setting terminal for the test mode |
|
| |
|
|
|
|
|
|
| |
41 |
| KEY4 | I | Key input terminal (A/D input) (S941 to S845) | FADER, PEAK SEARCH, CLEAR, CHECK, | ||
| EDIT keys input |
|
| ||||
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
42 |
| KEY3 | I | Key input terminal (A/D input) (S831 to S838) | DISC 5, DISC 4, DISC 3, DISC 2, DISC 1, | ||
| CONTINUE, SHUFFLE, PROGRAM keys input |
| |||||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
43 |
| KEY2 | I | Key input terminal (A/D input) (S821 to S827) | MEGA CONTROL, | ||
| MENU, | ||||||
|
|
|
|
| |||
|
|
|
|
|
| ||
44 |
| KEY1 | I | Rotary encoder key input terminal (A/D input) (S801, S811 to S815) lAMS L(DISC) | |||
| PUSH ENTER, H, X, s, | ||||||
|
|
|
|
| |||
|
|
|
|
|
|
| |
45 |
| NC | — | Not used (open) |
|
| |
|
|
|
|
|
| ||
46 |
| TSENS | I | Detect signal input from the table sensor (D10) |
| ||
|
|
|
|
| |||
47 |
| FLT | O | Serial data latch pulse output to the FL driver (IC801) | |||
|
|
|
|
| |||
48 |
| CLK | O | Serial data transfer clock signal output to the CXD2587Q (IC101) | |||
|
|
|
|
|
|
| |
49 |
| NC | O | Not used (open) |
|
| |
|
|
|
|
|
| ||
50 |
| DATA | O | Serial data output to the CXD2587Q (IC101) |
| ||
|
|
|
|
| |||
51 |
| SQCK | O | ||||
|
|
|
|
| |||
52 |
| SQSO | I | ||||
|
|
|
|
|
|
| |
53 |
| NC | — | Not used (open) |
|
| |
|
|
|
|
| |||
54 |
| SENSE | I | Internal status (SENSE) signal input from the CXD2587Q (IC101) | |||
|
|
|
|
|
|
| |
55 |
| NC | I | Not used (fixed at “H”) |
|
| |
|
|
|
|
| |||
56 |
| RMIN | I | Remote control signal input from the remote control receiver (IC802) | |||
|
|
|
|
|
|
|
|
34