4-1
DXC-190
Section 4Electrical Alignment
.ND Filter
ND25 (25 %) 50 by 50 mm square
.Make the transmission factor to 6.25 % with double ND
filter.
.Oscilloscope
.Frequency Counter
.Digital Voltmeter
.Vectorscope
.Waveform Monitor
.Color Monitor

4-1. Preparations

4-1-1. Equipment Required

J-6029-140-B Pattern Box PTB-500
. Light source for test chart
J-6431-100-A Vectorscope Scale
. For color adjustment
J-6430-530-A Board for Interface Tool
J-6020-250-A Color Bar Chart
. For color adjustment
J-6082-053-B Remote Commander, RM-95
. RM-95 partly converted
J-6080-053-A Color Temperature Correction Filter C14
. For the confirmation after the adjustment
Copy the last page on a transparent sheet.
R
YL
G
WB
B
CB
CY
MG
R-Y
B-Y
5600K
J-6431-100-A
WGC
Y
YI M
g
RB
J-6431-170-A Extension Flex Cable
. For the extension between FC board and PR board