4-9
DXC-190
3Set the ND filter (transmission factor: 6.25 %).
4Turn ON the AGC switch on the side panel of the
camera, and turn NORM the TURBO/NORM switch
5Shoot the all-white pattern. Check to see if the
VIDEO-OUT image level is within the specified value
range.
4Check to see if the white bright spot on the vector-
scope converges to meet the specified value.
*If there is a point where the specified value for step 5 is
satisfied while varying the lens iris within the specified
value range for step 2, the adjustment is correct.
Or, if there is a point where the specified value for step
5 is satisfied while varying the VIDEO LEVEL on the
side panel, the adjustment is correct.
4-5-7. Checking WB adjustment (3200Kpreset and data take-in)Checking ATW operation
1Set the WB switch on the camera side panel to the
ATW-PRO position, and turn OFF the AGC and CCD-
IRIS Switches.
2Set the C14 filter.
3Shoot the all-white pattern. Adjust the iris diaphragm
so that the VIDEO-OUT image level is set within the
specified value range.
4-5-8. Checking Color Reproduction
Adjustment
1Turn OFF the AGC and CCD-IRIS switches on the side
panel of the camera.
2Shoot the color bar chart.
3Adjust the iris diaphragm so that the VIDEO-OUT
white image level is set within the specified value
range.
4Check to see if the center of the bright spot of each of
the colors is within the color reproduction range.
*If there is a point where the specified value for step 4 is
satisfied while varying the lens iris within the specified
value range for step 3, the adjustment is correct.
All white pattern
Image level of VIDEO OUT
Waveform Monitor
65 ±3 IRE
Subject
Measurement point
Equipment
Specification
All white pattern
White bright spot of VIDEO OUT
Vectorscope
Within 30 seconds
Within a radius of 15 % of the vector-
scopes diameter of the origin
(Suppose the vectorscopes
diameter is 100 %.)
Subject
Measurement point
Equipment
Specifica-
tion
Conver-
gence time
5Remove the C14 filter and perform step 3 and step 4.
Conver-
gence spot
All white pattern
Image level of VIDEO OUT
Waveform Monitor
65 ±5 IRE
Subject
Measurement point
Equipment
Specification
Color Bar Chart
White image level VIDEO OUT
Waveform Monitor
90 ±2.5 IRE
Subject
Measurement point
Equipment
Specification
Subject
Measurement point
Equipment
Specification
Color Bar Chart
Respective color bright spot of VIDEO
OUT
Vector scope
The center of the bright spot for each
color is in its respective reproduction
range.