4-4 DXC-190
4-2. Adjustment Method

4-2-1. Preparations for Adjustment

(1) Setting switches:
.Set the Mode switch on the rear panel of the camera
to B position.
.Set the DIP switches on the side panel of the camera
to shown as below.
.Slide the sliding switch (HOLD) in the upper part of
the commander to the right side.
(2) Turn on the camera.
(3) Connecting the Commander:
Use a interface tool to connect the commander to the
connector (CN201) on the PR-229 board so that the
interface tool will have Pin 1 (white) coincide with Pin
1 (on the front panel side) of the connector.

4-2-2. Writing in Initial Data

(1) Press the START/STOP button in the upper part of the
commander.
(2) The numerals indicated on the LCD of the commander
will go out for a few seconds and then will reappear.
*In this stage, if the commander’s LCD display
remains out and cannot be restored, there is an
abnormality somewhere in the circuitry. Do not
proceed to adjustment without correcting the
abnormality.
If writing in initial data has been performed, be sure to
confirming data as follows.
(3) Press the MODE DISPLAY CHANGE button on the
commander to display Mode “5F”. Subsequently, press
the CHANGE DATA button to display Data “01”.
(4) Press the DATA write button of the commander.
(5) The numerals indicated on the LCD of the commander
will go out for a few seconds and then will reappear.
OFF
NORM
OFF
OFF
0
0
NORM
0
AGC
TURBO
BLC
SHUTTER
1 - A
1 - B
SHARP
180
WHT BAL
4-3. PRE ADJUSTMENT

4-3-1. 28MHz Adjustment

Subject Free
Measurement point PR Board TP201
Equipment Frequency Counter
Adjustment point PR Board CT201
Adjustment value 28.636363 MHz ±80 Hz
Adjustment procedures Operate an internal SYNC mode.

4-3-2. VCO Adjustment

Subject Unnecessary
Measurement point Oscilloscope
(DC 500 mV, 0.2 uS)
Equipment PR Board TP203
Adjustment point PR Board CT202
Adjustment value 1.7 ±0.1 V
Adjustment procedures Input the external sync signal to
the VS IN connector.

4-3-3. fsc Adjustment

Subject Free
Measurement point PR Board TP202
Equipment Frequency Counter
Adjustment point PR Board CT203
Adjustment value 3.579545 MHz ±20 Hz
Adjustment procedures Input the external SYNC signal
without Burst signal to VS IN
connector
4-4. Camera Adjustment

4-4-1. Setting up the Prepare for Adjustment

Mode

1Press the MODE DISPLAY CHANGE button on the
commander to display Mode “5F”. Subsequently, press
the CHANGE DATA button to display Data “01”.
2Press the MODE DISPLAY CHANGE button on the
commander to display Mode “61”. Subsequently, press
the CHANGE DATA button to display Data “01”.
Subject Unnecessary
Measurement point Nothing