Sony FWD-S47H1 manual Power On Batch, Answer Header Return to Data Size Data2 Data3 Check Sum

Models: FWD-S47H1

1 41
Download 41 pages 36.61 Kb
Page 21
Image 21

(b) Power On Batch

Syntax

Header

Category

Function

Data1

Data2

 

Data3

 

Check Sum

Control

0x8C

0x00

0x85

0x03

Input Select Code

Volume Code

0xXX

 

 

 

 

 

 

 

 

Table (1-a)[a]

 

Table (1-a)[b]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Syntax

Header

Category

Function

Data1

Data2

Check Sum

 

 

Enquiry

0x83

0x00

0x85

0xFF

0xFF

0xXX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Answer

Header

Answer

Check Sum

 

 

 

 

 

 

 

 

Control

0x70

0x00

0x70

Completed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0x70

0x01

0x71

Limit Over

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0x70

0x02

0x72

Limit Under

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0x70

0x03

0x73

Command Canceled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Answer

Header

Answer

Return to Data Size Data2

 

 

Data3

 

Check Sum

Enquiry

0x70

0x00

0x03

 

Input Select Code

Volume Code

0xXX

 

 

 

 

 

 

 

 

Table (1-a)[a]

Table (1-a)[b]

 

 

Code Table (1-a)

 

 

 

 

 

 

 

 

 

 

Input Select [a]*2 0x08

HD15 RGB

 

 

 

 

 

 

 

 

 

 

 

0x09

HD15 YUV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0x0E

Option RGB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0x0F

Option COMPONENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0x20

DVI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0x30

VIDEO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0x31

S-VIDEO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0x84

Option Digital1 (HDMI1/SDI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0x85

Option Digital2 (HDMI2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Volume [b]

 

0x00-0x64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code Table (1-b)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[a]Function

 

 

[b]Range/Switch code

Command

 

 

 

 

 

 

 

 

 

 

 

 

Control

Enquiry

Standby

Power On

0x85 Power On Batch

 

 

 

Yes

No

 

Enable

Control/Disable

*1 When this control command is received, the power of a set will be turned on first.

*2 Input Select setting, Auto Signal Detect becomes Disable. When Option Slot is connected, Option command is Enable.

FWD-S42H1

19

Page 21
Image 21
Sony FWD-S47H1 manual Power On Batch, Answer Header Return to Data Size Data2 Data3 Check Sum