Section 1
RS-232C
1. Communication Parameters
Communication method | |
|
|
Synchronous method | Asynchronous |
|
|
Baud rate | 9600bps |
|
|
Character length | 8bit |
|
|
Parity | None |
Start bit length | bit |
Stop bit length | bit |
|
|
Flow control | None |
|
|
2. Pin Assignment
Monitor side
5 4 3 2 1
9 8 7 6
Host side
5 4 3 2 1
9 8 7 6
_ External view _ |
| _ External view _ | ||
|
|
|
|
|
Pin No. | Function |
| Pin No. | Function |
1 | NC |
| 1 | NC |
2 | TXD |
| 2 | RXD |
| ||||
3 | RXD |
| 3 | TXD |
| ||||
4 | NC |
| 4 | NC |
5 | GND |
| 5 | GND |
| ||||
6 | NC |
| 6 | NC |
7 | NC |
| 7 | NC |
8 | NC |
| 8 | NC |
9 | NC |
| 9 | NC |
3. Communication Data Format
(a) Control message
No. | Item | Value |
1 | Header | 0x8C: Control |
|
|
|
2 | Category | 0xXX |
|
|
|
3 | Function | 0xXX |
4 | Data1 (Length) | 0xXX |
5 | Data2 (Data1) | 0xXX |
|
|
|
: | : | 0xXX |
|
|
|
: | : | 0xXX |
|
|
|
X | DataX | 0xXX |
|
|
|
X+1 | Check Sum | 0xXX |
*Check Sum: Sum total of 1 to X. Lower
*Set the command interval to 500 ms or more when transmitting the Control command continuously.
*Set the command interval to 500 ms or more when transmitting the same command (Enquiry) after the Control command.