KV-32S40/32S45/34SL40/34SL40C/34SL40T/34SL45/35S40/35S45/37SL45/ 32V40/32V65/34VL65/34VL65C/35V65/37VL65/37VL65C

SECTION 4

SAFETY RELATED ADJUSTMENTS

R530, R531 CONFIRMATION METHOD (HOLD-DOWN CONFIRMATION) AND READJUSTMENTS

Always perform the following adjustments when replacing the following components marked with a ] mark on the schematic diagram:

A BOARD: IC351, IC501, D519, D520, D521, C531, C532, R387, R529, R530, R531, R532, R533, R550, T503

G BOARD:

IC643, R661

 

 

Step 1 Preparation before Confirmation

Turn the POWER switch ON.

Input a white signal and set the PICTURE and BRIGHT controls to maximum.

Confirm that the voltage at the check terminal of TP85 is more than 18.0 V DC when the set is operating normally.

At AC input: 120.0 ± 2.0 VAC

or 220.0 ± 2.0 VAC (for 34SL40C/34VL65C/37VL65C only)

dejital

digitalmultimetermultimeter

+

-

TP85

T503

T503

R53R5131R530

FBT

 

11

ammetereter

+3mA DCdc rangege

DC Power Supply -

A

+ 1T40 -

A BOARD - CONDUCTOR SIDE

Step 2

Input a white signal and verify that I ABL is within the specified range: 2160 + 100 μA.

At AC input: 120.0 ± 2.0 VAC

or 220.0 ± 2.0 VAC (for 34SL40C/34VL65C/37VL65C only)

T504

FBT

ammeter

3.0 mA DC range

ABL + A -

I ABL

Step 3

Record the voltage between TP85 and ground.

Step 4

Using an external DC power supply, apply voltage between TP85 and ground.

Increase the voltage gradually and confirm that the holdown works (raster disappears) at lower than the voltage recorded in Step 3.

Lower than 22.05 V DC

At AC input: 120.0 ± 2.0 VAC

or 220.0 ± 2.0 VAC (for 34SL40C/34VL65C/37VL65C only)

Step 5

Confirm that a voltage of more than 18.0 V DC appears between TP85 and ground.

At AC input: 120.0 ± 2.0 VAC

or 220.0 ± 2.0 VAC (for 34SL40C/34VL65C/37VL65C only)

B+ VOLTAGE CONFIRMATION AND ADJUSTMENT

Always perform the following adjustments when replacing the following components marked with ]on the schematic diagram:

G BOARD: IC643, R661

1)Using Variac, apply AC input voltage: 130 + 2.0 VAC

(or 220.0 ± 2.0 VAC for 34SL40C/34VL65C/37VL65C only)

2)Input a monoscope signal.

3)Set the PICTURE control and the BRIGHT control to initial reset value.

4)Confirm the voltage of G BOARD CN641 between pin 1 to ground is less than 135.5 + 1.0 V DC.

5)If step 4 is not satisfied, replace the R661and repeat the above steps.