Sony MDS-JE640 specifications Adjustment flow, Yes

Models: MDS-JE640

1 66
Download 66 pages 17.66 Kb
Page 21
Image 21

Adjustment flow

Start

Replace IC195

NO

YES

• Abbreviation

OP: Optical pick-up

After turning off and then on the power, initialize the EEPROM

For details, refer to 4-11. WHEN MEMORY NG IS DISPLAYED (See page 19)

Replace OP or IO195

YES

5-7. INITIAL SETTING OF ADJUSTMENT VALUE (See page 26)

NO

Replace IC101, IC195, or D101

NO

YES

5-9. TEMPERATURE COMPENSATION OFFSET ADJUSTMENT (See page 26)

Replace OP, IC190, or IC195

YES

5-10. LASER POWER ADJUSTMENT (See page 26)

NO

Replace OP, IC102, IC190,

YES

5-11. Iop NV SAVE (See page 27)

 

 

or IC195

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

5-12.

TRAVERSE ADJUSTMENT (See page 27)

Replace OP, IC101, IC151,

5-13.

FOCUS BIAS ADJUSTMENT (See page 28)

 

 

or IC195

 

 

5-16.

AUTO GAIN CONTROL OUTPUT LEVEL

 

 

 

 

 

 

 

ADJUSTMENT (See page 29)

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace OP

NO

YES

OP change in Err Display mode Iop write

Replace the spindle motor

YES

Spdl change in Err Display mode

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5-6-4. Auto Check

 

 

 

 

 

(See page 24)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

End adjustments

 

 

 

 

21

Page 21