•MO Automatic Adjustment item
Mode No. | Description | |
112 |
| |
|
| |
113 | MO electrical offset adjustment | |
114 | ||
| ||
|
| |
118 |
| |
221 | Lower reflection CD tracking error gain adjustment | |
223 | Lower reflection CD tracking error offset adjustment | |
| ||
232 | ||
| ||
236 | Lower reflection CD ABCD level adjustment | |
|
| |
244 | Lower reflection CD focus gain adjustment | |
|
| |
245 | Lower reflection CD tracking gain adjustment | |
121 | MO tracking error gain adjustment | |
|
| |
122 | MO tracking error offset adjustment |
[Laser Power Check]
Connection :
laser power meter
Optical
digital voltmeter
R501
R501
134 | MO TWPP gain adjustment | |
131 | MO double speed read TWPP offset adjustment | |
| ||
132 | ||
| ||
136 | MO ABCD level adjustment | |
|
| |
144 | MO focus gain adjustment | |
145 | MO tracking gain adjustment | |
|
| |
434 | MO write TWPP gain adjustment | |
|
| |
431 | MO write TWPP offset adjustment | |
432 | ||
| ||
|
| |
436 | MO write ABCD level adjustment | |
445 | MO write tracking gain adjustment | |
|
| |
411 | MO normal speed read TWPP offset adjustment | |
412 | ||
| ||
448 | 32 cluster full recording | |
|
| |
141 | MO focus bias adjustment |
AP913 (VC)
C502
|
|
| R501 |
|
|
|
|
| 1 | |
|
|
|
| L502 |
|
| C712 | 5 | ||
|
|
|
|
|
|
| ||||
|
| L501 |
| R506 | C504 |
|
|
|
| |
|
|
| E C B |
|
| 10 | ||||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| 14 | ||
|
|
|
|
| Q501 |
|
|
| ||
|
| C501 |
|
|
|
|
|
| ||
|
|
|
| R502 | R504 | R503 |
| C716 | ||
509 | 508 | 507 | 513 | 512 | 505 |
|
MAIN BOARD (SIDE A)
56 | C709 |
|
|
45 | 43 |
| |
| 50 | 42 |
|
|
| C711 | |
|
| 40 | |
|
|
|
| IC701 |
|
| 35 |
|
|
|
| |
|
|
|
| 29 |
15 | 20 | 25 | 28 | C715 |
|
10.If the result of automatic adjustment is OK, the following dis- play appears in the LCD:
LCD display
M O O K
141
11.If the result of automatic adjustment is NG, the following dis- play appears in the LCD:
LCD display
# # # N G
## # : Overall adjustment. NG mode number
12.If NG, set the manual mode. Perform automatic adjustment for the items not accepted. (See page 13)
13.To clear the data in overall adjustment mode, set the manual mode and change the mode number 021 (Res NV) to reset the NV. (See page 13)
14.When both CD and MO overall adjustments are OK, set the mode No. 043 (Resume) and clear the clock data.
LCD display
R e s u m e
043
rPress the X key, historical data clear
R e s C l r
043
Note: In step 10, set the clock data to 99Y11M11D11H11M00S, and in step 14, do not set the clock.
Check Method :
1.Select the manual mode of test mode, and set the laser power adjusting mode. (mode number 010)
2.Press the . key continuously until the optical
3.Open the cover and set the laser power meter on the objective lens of the optical
4.Press the N key, and set the laser MO read adjustment mode. (mode number 011)
5.Check that the laser power meter reading is 0.81 ± 0.08 mW.
6.Check that the voltage both ends of resitor R501 at this time is below 44 mV.
7.Press the N key, and set the laser CD read adjustment mode. (mode number 012)
8.Check that the laser power meter reading is 0.97 ± 0.10 mW.
9.Check that the voltage both ends of resitor R501 at this time is below 44 mV.
10.Press the N key, and set the laser MO write adjustment mode. (mode number 013)
11.Check that the laser power meter reading is 4.95 ± 0.50 mW.
12.Check that the voltage both ends of resister R501 at this time is below 80 mV.
13.Press the x key.
14.Release the test mode.
23