MZ-DH10P

6. OVERALL ADJUSTMENT MODE

6-1. Operation of The Overall Adjustment Mode

1.Enter the test mode (Display Check mode).

2.Press the [VOL--]key to activate the Overall Adjustment mode where the LCD displays as shown below.

Display of the remote commander

000 AdjF**

Disc mark:

Lit the inner segments: Completed the power supply adjustment.

Lit the outer segments: Completed the check of charge function.

**”:

If “DF” or “FF” is displayed, it mean that completed the servo overall adjustment.

3.To release the Overall Adjustment mode, press the x key and return to the Display Check mode.

Flow of overall adjustment mode:

Overall Adjustment Mode

000 AdjF**

6-2. Error Message in The Overall Adjustment Mode

In the Overall Adjustment mode, if an error occurred, it displays as following table.

Display

Description

 

 

Close!

Dose not close the lid

 

 

DfDis!

Unsuitableness disc was inserted

 

 

NoChg!

Does not finish the check of charge function yet

 

 

NotCD!

Does not complete the CD Overall adjustment before the

 

MD1 Overall adjustment

 

 

NotM1!

Does not complete the MD1 Overall adjustment

 

before the Hi-MD3 Overall adjustment

 

 

NotH3!

Does not complete the Hi-MD3 Overall adjustment

 

before the Stray Light Offset Overall adjustment

 

 

****NG

Error of item number “****

 

 

7. SELF-DIAGNOSIS RESULT DISPLAY MODE

This set uses the self-diagnostic function system in which if an error occurred during the recording or playing, the mechanism control block and the power supply control block in the microcomputer detect it and record its cause as history in the nonvolatile memory. By checking this history in the test mode, you can analyze a fault and determine its location.

. key

CD Overall Adjustment Mode

Total recording time is recorded as a guideline of how long the

xkey

> key

xkey

*** CD Run

MD1 Overall Adjustment Mode

*** MD1Run

Hi-MD3 Overall Adjustment Mode

optical pick-up has been used, and by comparing it with the total recording time at the time when an error occurred in the self- diagnosis result display mode, you can determine when the error occurred.

Clear the total recording time, if the optical pick-up was replaced.

7-1. Operation of The Self-Diagnosis Result Display

[VOL +] key

xkey

[VOL --] key

xkey

[DISPLAY] key

xkey

*** HM3Run

Stray Light Offset Overall Adjustment Mode

*** OfsRun

Optical Pick-up Operation Check Mode

000 OPChk

Mode

1.Enter the test mode (Display Check mode).

2.Press the > key to activate the Self-Diagnosis Result Display mode where the LCD displays as shown below.

Display of the remote commander

*** $$####

***” : Error display code

$$” : Error rivision history code

####” : Addition information when error occurs

[DOWNLOAD] key Initialize The Adjustment Values

911 ResOK?

x key

rotation

3.To release the Self-Diagnosis Result Display mode, press the x key and return to the Display Check mode.

15