MZ-DH10P

SECTION 5

Ver. 1.1

ELECTRICAL ADJUSTMENTS

 

1.PRECAUTIONS FOR ADJUSTMENT

1.Adjustment must be done in the test mode only. After adjusting, release the test mode. A key having no particular description in the text, indicates a set key. Also, for the LCD display, the LCD on the remote commander is shown.

2.Use the following tools and measuring instruments.

Digital voltmeter

Regulated dc power supply (two sets)

Laser power meter

CD adjustment disc TDYS-1 (Part No. : 4-963-646-01)

MD1/HiMD1 hybrid adjustment disc MDW-74/GA2 (Part No. : J-2503-022-A)

Hi-MD3 adjustment disc HMD1GSDJ (Part No. : 8-892-388-38) *1

Remote commander in accessories (with LCD)

Battery charging stand and AC adapter in accessories

*1) Hi-MD3 adjustment disc (HMD1GSDJ) is consumable. Therefore if it is used 400 times, exchange it for a new.

2.ADJUSTMENT SEQUENCE

Adjustment must be done with the following order.

Adjustment order:

1.Entering the test mode

2.Initialize the adjustment value

3.Power supply voltage adjustment

4.Charge function check

5.Laser power check

6.Setting the adjustment values

7.Servo Overall adjustment

8.Resume clear

9.Releasing the test mode

3.ADJUSTMENT OF THE EACH ITEM 3-1. Entering The Test Mode

Refer to the “SECTION 4. TEST MODE”. (See page 13)

3-2. Initialize The Adjustment Value

Procedure:

1.In the test mode (Display Check mode), press the [VOL--]key to enter the Overall adjustment mode.

2.Press the [DOWNLOAD] key and display “911 ResOK?”.

3.

Press the

+

,

u ENT

key on the set or

key on the

 

remote commander to display “911 Reset!” and initialize the

 

adjustment values.

 

 

4.

Press the

x key and back to Display Check mode.

3-3. Power Supply Voltage Adjustment

Adjustment must be done with the following order.

3-3-1. Setting

Procedure:

1.Apply the voltage of 3.7 V to the battery terminals, and enter the test mode (Display Check mode).

2.Press the [VOL+] key to enter the Manual mode.

3.Press the [VOL+] key twice to display as follows.

Display of the remote commander

4.Press the > key once, press the [VOL+] key once, and press the > key once again to display as follows.

Display of the remote commander

210PwrAdj

5.Repeat the next procedures (3-3-2. PwrAdj Adjustments), and adjust all contents of “table 3-3-1. PwrAdj Specifications”.

3-3-2. PwrAdj adjustments

Repeat the following procedures and adjust all contents of “table 3- 3-1. PwrAdj Specifications”.

Example Display (Item No. 2211)

211 VC1

**

 

 

 

 

 

 

 

 

 

adjustment value (hexadecimal)

Procedure:

1.Connect the digital voltmeter to measuring point (refer to the following table) and TP461 (GND).

2.Press the > key to change the item numberr to 2211.

3.Adjust with [VOL+]/[VOL--]keys so that the value of digital voltmeter becomes specification value.

4. Press the

+

,

u ENT

key on the set or

 

key on the

remote commander to write the adjusted value.(Shifts to the

next item automatically)

 

 

 

5. Repeat adjustment from step 3 until item number 2233.

 

 

 

 

 

 

 

 

 

 

 

ItemNo.

Display

Specification value

 

Measuring point

 

 

 

 

 

 

 

 

 

 

 

2211

211 VC1 **

2.05V + 0.02V

 

 

TP8003

 

 

 

 

 

 

 

 

 

 

 

2212

212 VC1H N **

2.25V ± 0.01V

 

 

TP8003

 

 

 

 

 

 

 

 

 

 

 

2213

213 VC2 **

1.20V + 0.01V

 

 

TP602

 

 

 

 

 

 

 

 

 

 

 

2214

214 DDC3 L **

2.60V ± 0.015V

 

 

TP913

 

 

 

 

 

 

 

 

 

 

 

2215

215 DDC3 H **

3.10V ± 0.015V

 

 

TP913

 

 

 

 

 

 

 

 

 

 

 

2216

216 REG1 L **

2.32V ± 0.02V

 

 

TP901

 

 

 

 

 

 

 

 

 

 

 

2217

217 REG1 H **

3.02V ± 0.02V

 

 

TP901

 

 

 

 

 

 

 

 

 

 

 

2218

218 REG2 1 **

2.275V ± 0.01V

 

 

TP509

 

 

 

 

 

 

 

 

 

 

 

2219

219 REG2 2 **

2.480V ± 0.01V

 

 

TP509

 

 

 

 

 

 

 

 

 

 

 

2221

221 REG2 3 **

2.740V ± 0.01V

 

 

TP509

 

 

 

 

 

 

 

 

 

 

 

2222

222 REG2 4 **

2.985V ± 0.01V

 

 

TP509

 

 

 

 

 

 

 

 

 

 

 

2223

223 REG3 **

2.52V ± 0.02V

 

 

TP516

 

 

 

 

 

 

 

 

 

 

 

2224

224 VREC 1 **

0.89V ± 0.02V

 

 

TP601

 

 

 

 

 

 

 

 

 

 

 

2225

225 VREC 2 **

1.08V ± 0.02V

 

 

TP601

 

 

 

 

 

 

 

 

 

 

 

2226

226 VREC 3 **

1.52V ± 0.02V

 

 

TP601

 

 

 

 

 

 

 

 

 

 

 

2227

227 VREC 4 **

2.27V ± 0.02V

 

 

TP601

 

 

 

 

 

 

 

 

 

 

 

2228

228 VREC 5 **

2.97V ± 0.02V

 

 

TP601

 

 

 

 

 

 

 

 

 

 

 

2229

229 VREC 6 **

0.94V ± 0.02V

 

 

TP601

 

 

 

 

 

 

 

 

 

 

 

2231

231 VREC 7 **

1.28V ± 0.02V

 

 

TP601

 

 

 

 

 

 

 

 

 

 

 

2232

232 VREC 8 **

2.57V ± 0.02V

 

 

TP601

 

 

 

 

 

 

 

 

 

 

 

2233

233 VREC 9 **

2.57V ± 0.02V

 

 

TP601

 

 

 

 

 

 

 

 

 

 

 

Note1: **” is adjustment value (hexadecimal number).

Note2: Ground point of all measuring points is TP461.

Note3: Refer to page 18 for adjustment location.

Table 3-3-1. PwrAdj Specifications

002POWER

17