SECTION 5 | |
ELECTRICAL ADJUSTMENTS |
|
1.PRECAUTIONS FOR ADJUSTMENT
1.Adjustment must be done in the test mode only. After adjusting, release the test mode. A key having no particular description in the text, indicates a set key. Also, for the LCD display, the LCD on the remote commander is shown.
2.Use the following tools and measuring instruments.
•Digital voltmeter
•Regulated dc power supply (two sets)
•Laser power meter
•CD adjustment disc
•MD1/HiMD1 hybrid adjustment disc
•
•Remote commander in accessories (with LCD)
•Battery charging stand and AC adapter in accessories
*1)
2.ADJUSTMENT SEQUENCE
Adjustment must be done with the following order.
Adjustment order:
1.Entering the test mode
2.Initialize the adjustment value
3.Power supply voltage adjustment
4.Charge function check
5.Laser power check
6.Setting the adjustment values
7.Servo Overall adjustment
8.Resume clear
9.Releasing the test mode
3.ADJUSTMENT OF THE EACH ITEM
Refer to the “SECTION 4. TEST MODE”. (See page 13)
Procedure:
1.In the test mode (Display Check mode), press the
2.Press the [DOWNLOAD] key and display “911 ResOK?”.
3. | Press the | + | , | u ENT | key on the set or | – | key on the |
| remote commander to display “911 Reset!” and initialize the | ||||||
| adjustment values. |
|
| ||||
4. | Press the | x key and back to Display Check mode. |
Adjustment must be done with the following order.
Procedure:
1.Apply the voltage of 3.7 V to the battery terminals, and enter the test mode (Display Check mode).
2.Press the [VOL+] key to enter the Manual mode.
3.Press the [VOL+] key twice to display as follows.
Display of the remote commander
4.Press the > key once, press the [VOL+] key once, and press the > key once again to display as follows.
Display of the remote commander
210PwrAdj
5.Repeat the next procedures
Repeat the following procedures and adjust all contents of “table 3-
Example Display (Item No. 2211)
211 VC1 | ** |
| |
|
|
|
|
|
|
|
|
adjustment value (hexadecimal)
Procedure:
1.Connect the digital voltmeter to measuring point (refer to the following table) and TP461 (GND).
2.Press the > key to change the item numberr to 2211.
3.Adjust with
4. Press the | + | , | u ENT | key on the set or |
| – | key on the | |||
remote commander to write the adjusted value.(Shifts to the | ||||||||||
next item automatically) |
|
|
| |||||||
5. Repeat adjustment from step 3 until item number 2233. | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
ItemNo. | Display | Specification value |
| Measuring point | ||||||
|
|
|
|
|
|
|
|
|
|
|
2211 | 211 VC1 ** | 2.05V + 0.02V |
|
| TP8003 | |||||
|
|
|
|
|
|
|
|
|
|
|
2212 | 212 VC1H N ** | 2.25V ± 0.01V |
|
| TP8003 | |||||
|
|
|
|
|
|
|
|
|
|
|
2213 | 213 VC2 ** | 1.20V + 0.01V |
|
| TP602 | |||||
|
|
|
|
|
|
|
|
|
|
|
2214 | 214 DDC3 L ** | 2.60V ± 0.015V |
|
| TP913 | |||||
|
|
|
|
|
|
|
|
|
|
|
2215 | 215 DDC3 H ** | 3.10V ± 0.015V |
|
| TP913 | |||||
|
|
|
|
|
|
|
|
|
|
|
2216 | 216 REG1 L ** | 2.32V ± 0.02V |
|
| TP901 | |||||
|
|
|
|
|
|
|
|
|
|
|
2217 | 217 REG1 H ** | 3.02V ± 0.02V |
|
| TP901 | |||||
|
|
|
|
|
|
|
|
|
|
|
2218 | 218 REG2 1 ** | 2.275V ± 0.01V |
|
| TP509 | |||||
|
|
|
|
|
|
|
|
|
|
|
2219 | 219 REG2 2 ** | 2.480V ± 0.01V |
|
| TP509 | |||||
|
|
|
|
|
|
|
|
|
|
|
2221 | 221 REG2 3 ** | 2.740V ± 0.01V |
|
| TP509 | |||||
|
|
|
|
|
|
|
|
|
|
|
2222 | 222 REG2 4 ** | 2.985V ± 0.01V |
|
| TP509 | |||||
|
|
|
|
|
|
|
|
|
|
|
2223 | 223 REG3 ** | 2.52V ± 0.02V |
|
| TP516 | |||||
|
|
|
|
|
|
|
|
|
|
|
2224 | 224 VREC 1 ** | 0.89V ± 0.02V |
|
| TP601 | |||||
|
|
|
|
|
|
|
|
|
|
|
2225 | 225 VREC 2 ** | 1.08V ± 0.02V |
|
| TP601 | |||||
|
|
|
|
|
|
|
|
|
|
|
2226 | 226 VREC 3 ** | 1.52V ± 0.02V |
|
| TP601 | |||||
|
|
|
|
|
|
|
|
|
|
|
2227 | 227 VREC 4 ** | 2.27V ± 0.02V |
|
| TP601 | |||||
|
|
|
|
|
|
|
|
|
|
|
2228 | 228 VREC 5 ** | 2.97V ± 0.02V |
|
| TP601 | |||||
|
|
|
|
|
|
|
|
|
|
|
2229 | 229 VREC 6 ** | 0.94V ± 0.02V |
|
| TP601 | |||||
|
|
|
|
|
|
|
|
|
|
|
2231 | 231 VREC 7 ** | 1.28V ± 0.02V |
|
| TP601 | |||||
|
|
|
|
|
|
|
|
|
|
|
2232 | 232 VREC 8 ** | 2.57V ± 0.02V |
|
| TP601 | |||||
|
|
|
|
|
|
|
|
|
|
|
2233 | 233 VREC 9 ** | 2.57V ± 0.02V |
|
| TP601 | |||||
|
|
|
|
|
|
|
|
|
|
|
Note1: “**” is adjustment value (hexadecimal number).
Note2: Ground point of all measuring points is TP461.
Note3: Refer to page 18 for adjustment location.
Table
002POWER
17