Note1: When perform this check, don’t apply a voltage to battery terminals.
Note2: Be sure to disconnect the AC adapter when connecting the resistors. Doing so with the power supply connected causes a trouble.
Procedure:
1.Connect the 10 ohms resistor (more than 3 watts) to battery terminals.
2.Connect the AC adapter to the battery charging stand in accessories and set the main unit.
3.Enter the test mode (Display Check mode).
4.Press the [VOL+] key to enter the Manual mode.
5.Press the [VOL+] key twice, press the > key once, press the [VOL+] key once, press the > key once, press the [VOL+] key twice to display as follows.
Display of the remote commander
250ChrgLi
6.And > key once again to select the item number 2251 and display “251 ChgChk **” on the LCD of remote commander.
7. Press the + , u ENT key on the set or – key on the remote commander confirm that “ADJ OK” is displayed.
8.Press the x key four times and back to the Display Check mode.
9.Cut the power supply and remove the resistor that connected to the battery terminals.
Procedure:
1.Enter the test mode (Display Check mode).
2.Press the [VOL+] key to enter the Manual mode.
3.Open the lid and press the . key continuously until the optical
4.Press the
Display of the remote commander
009DESIGN
5.Press the > key three times to select the item number 9111 and display as follows.
Display of the remote commander
111 LrefPw **
6.Set the laser power meter so that the laser beam from the optical
7.Confirm that the value of laser power meter is 0.860 mW ± 19.2%.
8.Press the > key to select the item number 9112.
9.Confirm that the value of laser power meter is 0.763 mW ± 18.2%.
10.Press the > key to select the item number 9113.
11.Confirm that the value of laser power meter is 6.87 mW ± 12%.
12.Press the x key four times and back to the Display Check mode.
Preparation:
1.Perform calculation every item based on the data given by the
2.Convert the calculated value into hexadecimal number.
Note: The
Item No. | Calculating formula (*3) |
0211 | Pr_nominal / 0.05 |
|
|
(*1) | Por / 0.05 |
|
|
0212 | Kr ⋅ (−100) |
|
|
0213 | Pw_nominal / 0.05 |
|
|
(*2) | Ppw / 0.05 |
|
|
0214 | Kw ⋅ (−100) |
|
|
0215 | Prmin / 0.05 |
|
|
0216 | Pwmin / 0.05 |
|
|
*1) If the “Pr_nominal” value is indicated, use the “Pr_nominal” value and not used “Por” value.
*2) If the “Pw_nominal” value is indicated, use the “Pw_nominal” value and not used “Ppw” value.
*3) Round off after the decimal point.
Table
Example of Calculation:
Item No. | Parameter |
| Result | ||
|
| ||||
Decimal | Hexadecimal | ||||
|
|
| |||
|
|
|
|
| |
0211 | Pr_nominal | 2.48 mW | 50 | 32h | |
|
|
|
|
| |
0212 | Kr | −0.3 %/°C | 30 | 1Eh | |
|
|
|
|
| |
0213 | Pw_nominal | 7.35 mW | 147 | 93h | |
|
|
|
|
| |
0214 | Kw | −0.4 %/°C | 40 | 28h | |
|
|
|
|
| |
0215 | Prmin | 1.9 mW | 38 | 26h | |
|
|
|
|
| |
0216 | Pwmin | 5.8 mW | 116 | 74h |
Procedure:
1.Enter the test mode (Display Check mode).
2.Press the [VOL+] key to enter the Manual mode.
3.Press the > key once, press the [VOL+] key once, and press the > key once again to display as follows.
Display of the remote commander
210DiscPr
4.Press the > key once to select the item number 0211.
5.Adjust with
6. Press the | + | , | u ENT | key on the set or |
| – | key on the |
remote commander to write the adjusted value. |
|
|
7.Press the > key to next item.
8.Repeat adjustment from step 4 until item number 0216.
19