Conversion Instructions (Models CPL1100AD*, CGL1100AD*)

GAS CONVERSION

HOW TO REMOVE RANGE

 

FOR SERVICING

General

Follow these procedures to remove appliance for

All ranges are equipped with fixed orifices and with a

servicing:

convertible appliance pressure regulator. The unit model

1.

Shut off gas supply to appliance.

number plate states which gas it was adjusted for at the

 

 

factory. To convert the unit to either Natural gas or LP gas

2.

Disconnect electrical supply to appliance, if equipped.

will require the replacement of orifice hoods, adjustment

3.

Disconnect gas supply tubing to appliance.

of the air shutters on the burners and adjustment of the

4.

Slide range forward to disengage range from the

appliance pressure regulator converter cap.

 

 

anti-tip bracket. (See page 4).

SEE INSTRUCTIONS FOR GAS CONVERSION LOCATED ON THE BACK OF THE RANGE.

Inlet pressure to the appliance pressure regulator should be as follows for both operation and checking of appliance pressure regulator setting:

INLET PRESSURE IN

NATURAL

LP

INCHES OF WATER COLUMN

GAS

GAS

Minimum

5

11

Maximum

14

14

5.Reverse procedure to reinstall. If gas line has been disconnected, check for gas leaks after reconnection.

NOTE: A qualified servicer should disconnect and reconnect the gas supply.

The servicer MUST follow installation instructions provided with the gas appliance connector and the warning label attached to the connector.

6.To prevent range from accidentally tipping, range must be secured to the floor by sliding rear leveling leg into the anti-tip bracket.

SERVICE - PARTS INFORMATION

WHEN YOUR RANGE REQUIRES SERVICE OR REPLACEMENT PARTS, CONTACT YOUR DEALER OR AUTHORIZED SERVICE AGENCY. PLEASE GIVE THE COMPLETE MODEL AND SERIAL NUMBERS OF THE RANGE WHICH IS LOCATED ON THE RANGE MODEL NUMBER PLATE.

C–4

16023522

©2004 Maytag Services