Maytag CG31600ADB/Q/V, CPL1100ADH/L/Q/T/W, AGR5712ADB/Q/S/W manual Component Testing Procedures

Models: CGR1415ADH AGR4412ADB/Q/S/W CGR1110ADQ/W CGL1100ADQ/W CPR1100ADQ/W CGR1425ADH/Q/S/T/W CG31400ADW CG31600ADB/Q/V CGR1125ADQ/W AGR4400ADW CPL1110ADH/L/T AGR5712ADB/Q/S/W CPL1100ADH/L/Q/T/W

1 63
Download 63 pages 24.46 Kb
Page 18
Image 18
Manual background

Component Testing Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.

Diagnostic Code Checking

Code

Description

When Checked

Detection

1c1c

Shorted key

Always

1 minute

1c2c

Keyboard tail disconnected

Always

1 minute

1c31

Cancel key circuit problem

Always

20 seconds

1c6c

EEPROM error

When accessing EEPROM

3 tries

1c7c

Control not calibrated

Always

3 tries

1c8c

Cooking program error

Cook or clean programmed

3 tries

1d11

Runaway temp (650°F), door unlocked

Latch unlocked

1 minute

1d21

Runaway temp (950°F), door locked

Latch locked

1 minute

3d11

Sensor open

Cook or clean active

20 seconds

3d21

Sensor shorted

Cook or clean active

20 seconds

9d11

Latch will not lock

Latch should be locked

See Note 6

Diagnostic Code Handling

 

 

Code

Measurable

What is Displayed

Action Taken By Control

 

 

 

 

Disables audible for affected key

1c1c

Keypress

Nothing

 

depression

 

Disables all outputs 1, 2

 

 

 

 

Disables lights and timers

 

 

 

 

Disables audible for key depression

1c2c

Keyboard loop improper value

Nothing

 

Disables all outputs 1

 

 

 

 

Disables lights and timers

1c31

Cancel key improper value

BAKE flashes 3

Disables all outputs for cavity 1

1c6c

No response from EEPROM

Nothing

 

Disables all outputs 1

1c7c

Calibration value out of range

"CAL" in the time digits

Completely disables oven 4

1c8c

CRC invalid

Nothing

 

Cancels active cook function

1d11

Sensor resistance > 2237 Ohms

BAKE flashes 3

Disables all cook function for cavity

1d21

Sensor resistance > 2787 Ohms

BAKE flashes 3

Disables all cook function for cavity

3d11

Sensor resistance > Infinite Ohms

BAKE flashes 3

Disables all cook function for cavity

3d21

Sensor resistance > 0 Ohms

BAKE flashes 3

Disables all cook function for cavity

4d11

Door switch not closed when door is

Nothing

 

Disables Clean and Lockout

 

locked

 

functions 5

 

 

 

4d51

Door switch not open or closed

 

 

Disables Clean and Lockout

 

 

Nothing

 

functions 4, 5

 

 

 

Turn off light and disable light from

 

 

 

 

 

 

 

 

door switch

9d11

Lock switch not closed

LOCK flashes

3

Disables Clean and Lockout

 

 

functions 4

18

16023522

©2004 Maytag Services

Page 18
Image 18
Maytag CG31600ADB/Q/V, CPL1100ADH/L/Q/T/W, AGR5712ADB/Q/S/W, CPL1110ADH/L/T, AGR4400ADW manual Component Testing Procedures