a.Change the appliance pressure regulator from natural to LP setting. (See figure 12, 13 or 14).

b.Screw the burner orifice hoods down tight against the pins. (See figure 15B). Use care to not over tighten. Over tightening can damage the coaxial pin inside the orifice hood.

On units using Eaton Oven Safety Valve, screw the valve orifice hood down tight against the valve body. (See figure 15D). It is important that the hood be turned down as far as it can go to insure that complete conversion has occurred.

c.Models with standing pilots: Adjust burner pilots. (See figure 6). Turn the selector switch on the face of the thermostat to the LP position.

d.Adjust burner air shutter to the widest opening that will not cause the flame to lift or blow off the burner when cold.

Correctly adjusted sealed burners, can have flames that will lift or blow without a pot over the burner. These should be adjusted with a pot in place.

a.Change the appliance pressure regulator from LP to natural setting. (See figure 12, 13 or 14).

b.Screw the burner orifice hoods away from the pins. (See figure 15A). Approximately 1 1/2 to 2 turns.

On units using Eaton Oven Safety Valve, screw the burner orifice hoods away from pin (see figure 15C). Approximately 1 1/2 to 2 turns.

c.Models with standing pilots: Adjust top burner pilots. (See figure 6). Turn the selector switch on the face of the thermostat to the Nat. position.

d.Adjust burner air shutter to the widest opening that will not cause the flame to lift or blow off the burner when cold.

Correctly adjusted sealed burners, the flame will lift or blow without a pot over the burner. These should be adjusted with a pot in place.