Failed oven lamp

Troubleshooting Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.

Problem

Possible Cause

 

Failed oven lamp

 

Failed wiring

Oven light does not operate.

Failed light socket

 

 

Failed light plunger/switch

 

 

 

Oven is cleaning

 

Oven is still hot

Oven door will not unlock

 

 

 

Oven smokes/odor first few

Normal

times of usage

 

Failure Codes

Electronically Controlled

 

 

 

 

Power Outage

 

Improperly set oven controls

Part or all of the appliance

Oven door locked

does not work

 

 

Delayed cooking

 

 

Correction

Check lamp and replace is necessary.

Check for broken, loose or dirty connections.

Check light socket for continuity.

Check plunger/switch for continuity. Check wiring diagram for application.

Allow cycle to complete.

Door will not unlock until unit has cooled to safe temperature. Do not force door open, this will void warranty. Blow cool air on door latch area to quicken process.

Minor smoking and/or odor is normal the first few times of oven usage.

See Testing Procedures for diagnostic checks.

Check power supply/circuit breaker.

Verify oven controls are properly set.

Verify oven door is unlocked after a clean cycle.

Verify oven is not set for delayed cooking program.