Conversion Instructions (Models AGR4400AD*, AGR4412AD*, MGR4451AD*, MGR4452AD*, PGR4420LD*, CGR1425AD*, CGR1415AD*, CGR1110AD*, CP31600AD*)

Orifice Conversion

To convert the unit to either natural gas or LP gas will require the exchange of orifice hoods.

IMPORTANT: Save all parts removed in conversion.

Oven Burner Conversion

Remove all oven racks.

1.Bake Burner

a. Remove oven bottom (figure 2).

CLIP

Surface Burner Conversion (Sealed Burner)

1.Remove all grates.

2.Mark ignitor location on the main top with a pencil. This mark on the main top is used as a reference point when replacing the burner assembly to ensure that the burner is tightened to its original position.

3.Place burner wrench (part no. 8312D075-60, available from the dealer or authorized service agency) over the surface burner assembly with the ignitor positioned inside the gap in the wrench ring (figure 3). This prevents the ignitor from being damaged when the wrench grips the burner assembly. Rotate the burner assembly approximately one-eighth turn counter-clockwise and lift from the main top.

FIGURE 2

b. Remove screw from the front of the bake burner.

c.Remove the bake burner from the orifice fitting. CAUTION: The igniter is fragile. Take care not to damage it.

d.Gently lay the bake burner in the bottom of the range.

e.Remove the bake orifice hood with a ½￿ (12.7 mm) socket wrench counter-clockwise.

f.Place the black-colored orifice stamped .0512 for LP (.0810 for natural) on the fitting turning it clockwise by hand approximately one turn. Tighten the orifice hood with a ½￿ (12.7 mm) socket wrench clockwise approximately 2½ turns.

g.Replace the bake burner.

h.Replace the oven bottom.

FIGURE 3

4.Remove the surface burner orifice hood with a ½￿ (12.7 mm) socket wrench counter-clockwise.

IMPORTANT: Save all parts removed in conversion.