Component Testing Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.

Illustration

Component

Test Procedure

Results

 

Spark module

Test for voltage at terminals

 

 

4 + 0

L and N

120 VAC

GND

Input

Polarity and ground

Not subject to polarity

L or N

 

 

 

Spark module

Test for voltage at terminals

120 VAC

 

2 + 0

 

 

 

CGL1100AD*

Polarity and ground

Not subject to polarity

 

Holder orifice

Verify gas pressure (WCP)

4" Natural

 

 

Check orifice for debris

10" LP/Propane

 

 

Clean as needed.

 

Shut-off Valve

Verify gas supply is turned on.

Gas is turned on.

 

Shut-off Valve

Verify gas supply is turned on.

Gas is turned on.

 

Model CPL1100AD*

 

 

 

270° valve

Verify gas is supplied.

 

 

 

Orifice adjusted for Natural or LP.

 

 

 

Adjust set screw for simmer control

Refer to LP/Nat. conversion instructions.

 

Spark 270° switch

Unplug switch harness at rear of

120 VAC

 

 

range. Test for continuity at wire

 

 

 

terminals.

 

 

 

Switch in LITE position

Continuity

 

 

Switch in any other position

Infinite

 

Spark switch

Unplug switch harness at rear of

120 VAC

 

Model CGL1100AD*

range. Test for continuity at wire

 

 

 

terminals.

 

 

 

Switch in LITE position

Continuity

 

 

Switch in any other position

Infinite

 

Sealed burner

Verify gas is supplied

Gas present.

 

 

Check for obstructions or

 

 

 

contamination in burner ports

Clean/remove any foreign objects.

 

 

 

Check ignitor for bending/cracking.

 

Open burner

Verify gas is supplied

Gas present.

 

Model CPR1100AD*,

 

 

 

LPR1115AD*,

Verify air shutter adjusted properly

Air shutter opening: .400" to .500".

 

CP31200AD*,

 

 

 

CG31200AD*

 

 

 

Open burner

Verify gas is supplied

Gas present.

 

Models CPL1100AD*,

 

 

 

CGL1100AD*

Verify air shutter adjusted properly

Air shutter opening: .435" to .565".

 

Open burner

Verify gas is supplied

Gas present.

 

Model CGR1110AD*

 

 

 

 

Verify air shutter adjusted properly

Air shutter opening: .420" to .460".

 

Pilot burner

Verify pilot selector cartridge is set to

 

 

Models CPL1100AD*,

the proper gas

LP or Natural

 

CPR1100AD*,

 

 

 

LPR1115AD*,

 

 

 

CP31200AD*,

 

 

 

CG31200AD*

 

 