Maytag CGR1425ADH/Q/S/T/W, CPL1100ADH/L/Q/T/W, CPL1110ADH/L/T Orifice Hood, Lock Screw Air Shutter

Models: CGR1415ADH AGR4412ADB/Q/S/W CGR1110ADQ/W CGL1100ADQ/W CPR1100ADQ/W CGR1425ADH/Q/S/T/W CG31400ADW CG31600ADB/Q/V CGR1125ADQ/W AGR4400ADW CPL1110ADH/L/T AGR5712ADB/Q/S/W CPL1100ADH/L/Q/T/W

1 63
Download 63 pages 24.46 Kb
Page 59
Image 59
LOCK

Conversion Instructions (Models AGR5712AD*, CG34800AD*, CGR3725AD*, MGR5751AD*, MGR5752AD*, PGR5720LD*)

4. Remove the surface burner orifice hood with a ￿ (12.7

mm)socket wrench counter-clockwise.

:Save all natural orifice hoods that are

removed.

5.Place the corresponding orifice hood on the burner fitting according to figure 6. Turn the orifice hood clockwise by hand approximately one turn. Tighten the

orifice hood clockwise with a ￿ socket wrench approximately 2 turns.

6.Replace the burner assembly in the main top and rotate one-eighth turn clockwise using the burner wrench until the burner locks in place with the igniter aligned with the reference mark on the main top.

7.Repeat steps 3 through 6 until all orifice hoods have been changed.

7.2K BTU NATURAL (BLUE)

9.2K BTU NATURAL (NO COLOR)

REPLACE WITH ORIFICE (BLUE)

REPLACE WITH ORIFICE (NO COLOR)

STAMPED .0310 FOR LP

STAMPED .0335 FOR LP

9.2K BTU NATURAL (NO COLOR)

12K BTU NATURAL (RED)

REPLACE WITH ORIFICE (RED)

REPLACE WITH ORIFICE (NO COLOR)

STAMPED .0335 FOR LP

STAMPED .0350 FOR LP

a. The approximate length of the flame of oven burner is a 1/2 inch distinct inner blue flame, figure 8.

b. Oven burner flame can be checked as follows:

1.Yellow flame on burner - open burner air shutter to the widest opening that will not cause the flame to lift or blow off the burner when cold. (See #2 on figure 9.)

2.Distinct blue flame but lifting - close burner air shutter to the point where it will not cause the flame to lift or blow off the burner when cold. (See #2 on figure 9.)

3

LOCK

SCREW

AIR SHUTTER

FRONT OF MAINTOP

 

ART. #9215-250-1

 

 

 

1

2

ORIFICE

HOOD

Replace burner assembly in main top and rotate approximately one-eighth turn clockwise using burner wrench until burner locks into position with ignitor aligned with reference mark on main top.

ORIFICE HOOD

c.The oven burner air shutter adjustment is the same on ranges with a gas pilot or electric ignition.

d.Sealed burner adjustment. Adjust the air shutter for the appropriate gas according to figure 10.

AIR SHUTTER NATURAL POSITION

AIR SHUTTER

LP POSITION

©2004 Maytag Services

16023522

C–11

Page 59
Image 59
Maytag CGR1425ADH/Q/S/T/W manual Orifice Hood, Lock Screw Air Shutter, Air Shutter Natural Position Air Shutter Lp Position