Conversion Instructions (Models AGR4400AD*, AGR4412AD*, MGR4451AD*, MGR4452AD*, PGR4420LD*, CGR1425AD*, CGR1415AD*, CGR1110AD*, CP31600AD*)
Air Shutter
a. The approximate length of the flame of oven burner is a 1/2 inch distinct inner blue flame, figure 7.
FIGURE 7
b. Oven burner flame can be checked as follows:
1.Yellow flame on burner - open burner air shutter to the widest opening that will not cause the flame to lift or blow off the burner when cold. (See #2 on figure 8.)
2.Distinct blue flame but lifting - close burner air shutter to the point where it will not cause the flame to lift or blow off the burner when cold. (See #2 on figure 8.)
3
LOCK
SCREW
AIR SHUTTER
c.The oven burner air shutter adjustment is the same on ranges with a gas pilot or electric ignition.
d.Sealed burner adjustment. Adjust burner air shutter to the widest opening that will not cause the flame to lift or blow off the burner when cold according to figure 9.
NOTE: Correctly adjusted sealed burners, can have flames that will lift or blow without a pot over the burner. These should be adjusted with a pot in place.
AIR SHUTTER
NATURAL POSITION
AIR SHUTTER
LP POSITION
FIGURE 9
e. Conventional burner adjustment. Open the air shutters or the burners so that the square hole is completely uncovered (see figure 10).
AIR
SHUTTER
3/4 FLAME
ORIFICE
HOOD
1
2
ORIFICE
HOOD
FIGURE 8
Conventional Burners
FIGURE 10