Maytag CGR1125ADQ/W Quick Test Mode for Electronic Range Control, Description of Error Codes

Models: CGR1415ADH AGR4412ADB/Q/S/W CGR1110ADQ/W CGL1100ADQ/W CPR1100ADQ/W CGR1425ADH/Q/S/T/W CG31400ADW CG31600ADB/Q/V CGR1125ADQ/W AGR4400ADW CPL1110ADH/L/T AGR5712ADB/Q/S/W CPL1100ADH/L/Q/T/W

1 63
Download 63 pages 24.46 Kb
Page 17
Image 17
"Quick Test" Mode for Electronic Range Control

Component Testing Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.

"Quick Test" Mode for Electronic Range Control

Follow procedure below to use the quick test mode. Entries must be made within 32 seconds of each other or the control will exit the quick test mode.

1.Press and hold Cancel and Broil pads for 3 seconds.

2.Once the control has entered the "Quick Test" mode, release both pads.

3.Press each of the following pads indicated in the table below.

NOTE: First time one of following pads are pressed it will activate the response.

The second time the pad is pressed it will deactivate the response.

NOTE: This mode can only be entered within the first 5 minutes after power up.

NOTE: If the temperature sensor is greater than 400° F and the "Quick Test" mode will be disabled if the temperature sensor reaches 400° F while under test.

Display will indicate the following:

Key

Operation

[Bake]

Bake relay activated

[Broil]

Broil relay activated

[Keep Warm]

N\A

[Cook&Hold]

Last Diagnostic Code displayed

[Clean]

Beep sounds

[Delay] (M1)

EEPROM Version Number displayed

[Timer]

Main Code Version Number displayed

[Clock]

All Segments On

[More +]

Even Segments On

[Less –]

Odd Segments On

[Cancel]

End Factory Test Mode

Description of Error Codes

Error diagnostic codes can only be viewed by entering the Diagnostic Code Display Mode. Each error code is four digits long and is created based on the following table.

Digit

 

 

Description

1st

Primary System:

1 – Local to the control circuit board

 

 

3

– Sensor or meat probe

 

 

4

– Control input

 

 

9

– Door lock

2nd

Measurable:

d – Diagnostic: measurable parameter

 

 

c – Control related, replace control

3rd

Secondary System: Sequential numbering

4th

Oven Cavity:

1 – Upper oven (or single cavity oven)

 

 

2

– Lower oven

 

 

c – Control specific

Diagnostic Code Display Mode may be started only within 60 seconds when powering up the control.

©2004 Maytag Services

16023522

17

Page 17
Image 17
Maytag CGR1125ADQ/W, CPL1100ADH/L/Q/T/W Quick Test Mode for Electronic Range Control, Display will indicate the following