Maytag CPL1110ADH/L/T, CPL1100ADH/L/Q/T/W Orifice Conversion, From Natural Gas To LP/Propane Gas

Models: CGR1415ADH AGR4412ADB/Q/S/W CGR1110ADQ/W CGL1100ADQ/W CPR1100ADQ/W CGR1425ADH/Q/S/T/W CG31400ADW CG31600ADB/Q/V CGR1125ADQ/W AGR4400ADW CPL1110ADH/L/T AGR5712ADB/Q/S/W CPL1100ADH/L/Q/T/W

1 63
Download 63 pages 24.46 Kb
Page 54
Image 54
Orifice Conversion

Conversion Instructions (Model CPR1100AD*)

Orifice Conversion

From Natural Gas To LP/Propane Gas:

a. Change the appliance pressure regulator from Natural to LP setting (see figure 1).

b.Adjust oven thermostat (see figure 2).

1.Remove the main top and the manifold panel.

2.With a flat blade screwdriver turn pilot flame screw and bypass screw counter- clockwise to loosen. Use pliers to remove screws.

NOTE: Save all parts removed in conversion.

3.Replace the bypass screw with the #51 bypass screw. Use a flat blade screwdriver and turn clockwise until seated.

4.Replace the pilot screw with the #15 screw. Use a flat blade screwdriver and turn clockwise until seated.

5.Replace the manifold panel.

c.Adjust top burners (see figure 3).

1.Remove all (4) surface burners.

2.Remove all (4) orifice hoods from the valve by using a 1/2￿ wrench or socket and turning the hood counter- clockwise.

NOTE: Save all parts removed in conversion.

3.Replace with the brass colored hoods stamped

.85 mm by using a 1/2￿ wrench or socket and turning the hood clockwise approximately (6) complete turns.

4.Replace surface burners.

5.Open the air shutters on the burners so that the square hole is completely uncovered (see figure 6).

d.Adjust oven burner (see figure 4).

1.Remove oven racks and oven bottom.

2.Remove the oven burner by removing the screw from the pilot bracket and the oven burner bracket (see figure 4). Use caution in removing pilot bracket.

3.Remove orifice hood with 1/2￿ wrench or socket by turning counter-clockwise.

4.Replace with orifice hood with a black stripe stamped 1.3 mm using a 1/2￿ wrench or socket and turning the hood clockwise approximately (6) complete turns.

5.Replace oven burner and pilot bracket.

e.Pilot and burner adjustments - see section on “Range Adjustments”.

f.Replace oven bottom, oven racks, and main top.

From LP/Propane Gas To Natural Gas:

a. Change the appliance pressure from LP to Natural setting (see figure 1).

b. Adjust oven thermostat (see figure 2).

1.Remove the main top and the manifold panel.

2.With a flat blade screwdriver turn pilot flame screw and bypass screw counter- clockwise to loosen. Use pliers to remove screws.

NOTE: Save all parts removed in conversion.

3.Replace the bypass screw with the #76 bypass screw. Use a flat blade screwdriver and turn clockwise until seated.

4.Replace the pilot screw with the #31 screw. Use a flat blade screwdriver and turn clockwise until seated.

5.Replace the manifold panel.

c.Adjust top burners (see figure 3).

1.Remove all (4) surface burners.

2.Remove all (4) orifice hoods from the valve by using a 1/2￿ wrench or socket and turning the hood counter- clockwise.

NOTE: Save all parts removed in conversion.

3.Replace with the brass colored hoods stamped

.54 by using a 1/2￿ wrench or socket and turning the hood clockwise approximately (6) complete turns.

4.Replace surface burners.

5.Close the air shutters on the burners so that 1/4￿ of the square hole is covered (see figure 4).

d.Adjust oven burner (see figure 4).

1.Remove oven bottom.

2.Remove the oven burner by removing the screw from the pilot bracket and the oven burner bracket (see figure 4).

3.Remove orifice hood with 1/2￿ wrench or socket by turning counter-clockwise.

4.Replace with orifice hood with a brass hood stamped #46 using a 1/2￿ wrench or socket and turning the hood clockwise approximately (6) complete turns.

5.Replace oven burner and pilot bracket.

e.Pilot and burner adjustments - see section on “Range Adjustments”.

f.Replace oven bottom, oven racks, and main top.

SCREWS

PILOT FLAME SCREW

BYPASS SCREW

ORIFICE - Nat.: Brass Stamped #54

 

 

 

 

LP: Brass Stamped .85mm

 

 

 

OVEN

 

 

 

 

 

 

BURNER

 

 

 

 

 

AIR SHUTTER

 

Gas Type

Screw Type

Head Number

 

 

 

 

 

 

 

ORIFICE

 

Natural

Bypass

76

 

FIGURE 2

 

 

 

 

LP: Black Stripe Stamped 1.3mm

LP

Bypass

51

 

 

FIGURE 3

Nat.: Brass Stamped #46

 

 

 

 

 

Natural

Pilot

31

 

 

 

 

FIGURE 4

 

LP

Pilot

15

 

 

 

 

C–6

16023522

©2004 Maytag Services

Page 54
Image 54
Maytag CPL1110ADH/L/T manual Orifice Conversion, From Natural Gas To LP/Propane Gas, From LP/Propane Gas To Natural Gas