Conversion Instructions (Model CPR1100AD*)

Gas Conversion

How To Remove Range For Servicing

Follow these procedures to remove appliance for servicing:

1.Shut off gas supply to appliance.

2.Disconnect electrical supply to appliance, if equipped.

3.Disconnect gas supply tubing to appliance.

4.Slide range forward to disengage range from the anti-tip bracket.

5.Reverse procedure to reinstall. If gas line has been disconnected, check for gas leaks after reconnection.

NOTE: A qualified servicer should disconnect and reconnect the gas supply.

The servicer MUST follow installation instructions provided with the gas appliance connector and the warning label attached to the connector.

6.To prevent range from accidentally tipping, range must be secured to the floor by sliding rear leveling leg into the anti-tip bracket.

Service - Parts Information

When your range requires service or replacement parts, contact your dealer or authorized service agency. Please give the complete MODEL and SERIAL numbers of the range which is located on the range model number plate.

General

All ranges are equipped with fixed orifices and with a convertible appliance pressure regulator. The unit model number plate states which gas it was adjusted for at the factory. To convert the unit to either Natural Gas or LP Gas will require replacement of the orifice hoods, adjustment of the air shutters on the burners and adjustment of the appliance pressure regulator converter cap or plunger.

Inlet pressure to the appliance pressure regulator should be as follows for both operation and checking of appliance pressure regulator setting:

INLET PRESSURE IN

NATURAL

LP

INCHES OF WATER COLUMN

GAS

GAS

Minimum

5

11

Maximum

14

14

Appliance Pressure Regulator Conversion

The unit appliance pressure regulator must be set to match the type of gas supply used. If converting from Natural Gas to LP Gas, the appliance pressure regulator must be converted to regulate LP Gas. If converting from LP Gas to Natural Gas, the appliance pressure regulator must be converted to regulate Natural Gas.

To Convert The Appliance Pressure Regulator From One Gas To Another:

Remove cap, turn converter cap or plunger over and replace cap. (See figure 1).

LPG

NAT

FIGURE 1

NOTE: What you read on the converter cap or plunger after conversion is the type gas setting for that regulator, i.e. If you read NAT. the regulator is set for Natural Gas.

8101P635-60

(05-04-00)

©2004 Maytag Services

16023522

C–5

Page 53