Test Procedure

Results

 

Oven light socket

Test continuity of receptacle terminals ...

Indicates continuity with bulb inserted.

 

 

Measure voltage at oven light

120 VAC, see wiring diagram for terminal

 

 

 

identification.

 

 

 

If no voltage present, check wiring.

 

Rocker switch

Measure continuity of switch positions:

 

 

 

Closed

Continuity

 

 

Open

Infinite

 

Door lock switch

Switch connection in following

Normally Open

NC

 

positions: Not engaged

COM-NO=Open, COM-NC=Closed

COM

 

NO

 

 

 

 

 

Engaged

COM-NO=Closed, COM-NC=Open

 

Manual Latch

Disconnect wires and test for

 

 

assembly with switch

continuity per wiring diagram

See wiring diagram for schematic layout.

 

 

 

Refer to Parts Manual for replacement

 

 

 

components.

 

 

 

NOTE: Control will cancel function if

 

 

 

latch is moved to LOCK position during

 

 

 

Bake or Broil.

 

Bake burner

Verify gas is supplied.

Air shutter opening: .469" to .531".

 

 

Verify proper orifice installed-Nat or LP ..

Blue flame with no yellow tipping.

 

 

Check for obstructions, contamination

 

 

 

in ports or damage

Replace if punctured or torn.

 

Bake burner

Verify gas is supplied.

Air shutter opening: .349" to .411".

 

Models CPL1100AD*,

Verify proper orifice installed-Nat or LP ..

Blue flame with no yellow tipping.

 

CGL1100AD*

Check for obstructions, contamination

 

 

 

in ports or damage

Replace if punctured or torn.

 

Broil burner

Verify gas is supplied.

Air shutter opening: .281" to .343".

 

 

Verify proper orifice installed-Nat or LP ..

Blue flame with no yellow tipping.

 

 

Check for obstructions, contamination

 

 

 

in ports or damage

Replace if punctured or torn.

 

Ignitor

Test for voltage at terminals

120 VAC

 

 

Test for amount of amperage in circuit ...

3.2 to 3.6 Amps.

 

 

(Ignitor may glow, but not have

 

 

 

sufficient amperage to open valve).

 

 

Temperature sensor

Measure resistance

Approximately 1000 at room

 

 

 

temperature 80°F.

 

Gas thermostat

Test for voltage at terminals

120 VAC

 

Models AGR4400AD*,

 

 

 

CGR1415AD*,

 

 

 

CGR1110AD*,

 

 

 

CGL1100AD*,

 

 

 

CPL1100AD*,

 

 

 

CP31200AD*,

 

 

 

CG31200AD*,

 

 

 

CG31400AD*

 

 

 

Gas thermostat

Test for voltage at terminals

120 VAC

 

Model CPR1100AD*

 

 

 

Pressure regulator

Verify gas pressure (WCP)

4" Natural

 

 

If using LP service, verify proper gas

10" LP/Propane

 

 

 

 

 

supply conversion.

 

 

Spark ignition

Test for resistance of spark lead

Continuity

 

electrode

 

 

 

 

Test ignitor to chassis

No continuity from ignitor to chassis.