Installation Instructions (All models except CPL1100AD*, CGL1100AD*, CP31200AD*, CG31200AD*, LPR1115AD*)

(See figure 6)

Purge all air from supply system by turning on one top burner valve. Then turn off valve and adjust top pilot flame using adjusting screw “A” (figure 6) so that flame is even with top of flash tube. To light the burner, push and turn top burner knob to the lite position. NOTE: Some models have ONLY one pilot adjustment at the manifold pipe.

The approximate height of the

flame at the high or full-on position is shown below.

Adjust burner air shutter to the widest opening that will not cause the flame to lift or blow off the burner when cold. NOTE: Correctly adjusted sealed burners, can have flames that will lift or blow off without a pot over the burner. These should be adjusted with a pot in place.

3/4￿ FLAME

￿￿￿￿￿￿ ￿

To operate, push and turn top burner knob to the LITE position. The top burner will light. To turn OFF spark after the top burner has ignited turn knob to HI setting.

￿￿￿￿￿￿ ￿

-7-

A–11

16023522

©2004 Maytag Services

Page 36
Image 36
Maytag CGR1110ADQ/W, CPL1100ADH/L/Q/T/W, AGR5712ADB/Q/S/W, CPL1110ADH/L/T, AGR4400ADW, CGR1125ADQ/W, CG31600ADB/Q/V manual Flame