25)Select manual mode of the test mode, and set item number 874 (see page 14).
Remote commander LCD display
874 V6 dat **
**: Adjusted value
26)Adjust with the [VOLUME +] key (adjusted value up) or [VOL- UME
27)Press the X key to write the adjusted value.
Power Supply Manual Adjustment
• Adjustment sequence
Adjustment must be done with the following steps.
1.Vc PWM Duty (L) adjustment (item number: 762) r
2.Vc PWM Duty (H) adjustment (item number: 763) r
3.Vl PWM Duty (L) adjustment (item number: 764) r
4.Vl PWM Duty (H) adjustment (item number: 765) r
5.Vrec PWM Duty (L) adjustment (item number: 766) r
6.Vrec PWM Duty (H) adjustment (item number: 767) r
7.Vd PWM Duty adjustment (item number: 768)
• Setting method of power supply manual adjustment
1.Make sure that the power supply voltage is 3V.
2.Select the manual mode of the test mode (see page 14).
3.Set item number.
•Adjustment method of Vc PWM Duty (L) (item number: 762)
Remote commander LCD display
762 VclPWM **
**: Adjusted value
1.Connect a digital voltmeter to the AP914 (VC) on the MAIN board, and adjust [VOLUME +] key (voltage up) or [VOLUME
digital voltmeter
MAIN board
AP914 (VC)
AP912 (GND)
2. Press the X key to write the adjusted value.
Adjustment and Connection Location: MAIN board (see page 24)
•Adjustment method of Vc PWM Duty (H) (item number: 763)
Remote commander LCD display
763 VchPWM **
**: Adjusted value
1. Connect a digital voltmeter to the AP914 (VC) on the MAIN board, and adjust [VOLUME +] key (voltage up) or [VOLUME
MAIN board
AP914 (VC)
AP912 (GND)
2. Press the X key to write the adjusted value.
Adjustment and Connection Location: MAIN board (see page 24)
•Adjustment method of Vl PWM Duty (L) (item number: 764)
Remote commander LCD display
764 VLpwmL **
**: Adjusted value
1.Connect a digital voltmeter to the AP915 (VL) on the MAIN board, and adjust [VOLUME +] key (voltage up) or [VOLUME
–0.01
digital voltmeter
MAIN board
AP915 (VL)
AP912 (GND)
2. Press the X key to write the adjusted value.
Adjustment and Connection Location: MAIN board (see page 24)
•Adjustment method of Vl PWM Duty (H) (item number: 765)
Remote commander LCD display
765 VLpwmH **
**: Adjusted value
1.Connect a digital voltmeter to the AP915 (VL) on the MAIN board, and adjust [VOLUME +] key (voltage up) or [VOLUME
digital voltmeter
MAIN board
AP915 (VL)
AP912 (GND)
2. Press the X key to write the adjusted value.
Adjustment and Connection Location: MAIN board (see page 24)
22