![766 RECpwL **](/images/new-backgrounds/26137/2613745x1.webp)
•Adjustment method of Vrec PWM Duty (L) (item number: 766)
Remote commander LCD display
766 RECpwL **
**: Adjusted value
1.Connect a digital voltmeter to the AP611 (VREC) on the MAIN board, and adjust [VOLUME +] key (voltage up) or [VOLUME
+ 0.025
digital voltmeter
MAIN board
AP611 (VREC)
AP912 (GND)
2. Press the X key to write the adjusted value.
Adjustment and Connection Location: MAIN board (see page 24)
•Adjustment method of Vrec PWM Duty (H) (item number: 767)
Remote commander LCD display
767 RECpwH **
**: Adjusted value
1.Connect a digital voltmeter to the AP611 (VREC) on the MAIN board, and adjust [VOLUME +] key (voltage up) or [VOLUME
digital voltmeter
MAIN board
AP611 (VREC)
AP912 (GND)
2. Press the X key to write the adjusted value.
Adjustment and Connection Location: MAIN board (see page 24)
•Adjustment method of Vd PWM Duty (item number: 768)
Remote commander LCD display
768 VD_PWM **
**: Adjusted value
1.Connect a digital voltmeter to the AP911 (VD) on the MAIN
board, and adjust [VOLUME +] key (voltage up) or [VOLUME
V.
MAIN board
AP911 (VD)
AP912 (GND)
2. Press the X key to write the adjusted value.
Adjustment and Connection Location: MAIN board (see page 24)
Temperature Correction
• Adjustment method of temperature correction
1.Select the manual mode of test mode, and set the item number 015 (see page 14).
Remote commander LCD display
015 SetTmp **
**: Adjusted value
2.Measure the ambient temperature.
3.Adjust with [VOLUME +], [VOLUME
perature.
(Initial value: 19h = 25 ° C, Adjusting range: 80h to 7fh
4.Press the X key to write the adjusted value.
Laser Power Check
Connection :
laser power meter
Optical
digital voltmeter
MAIN board
TP (+)
TP
Checking Method :
1.Select the manual mode of test mode (see page 14), and set the laser power adjusting mode (item number 010).
Remote commander LCD display
010Laser
2.Press the . key continuously until the optical
3.Open the cover and set the laser power meter on the objective lens of the optical
4.Press the N key, and set the laser MO read adjustment mode (item number 011).
Remote commander LCD display
011 LrefPw **
5.Check that the laser power meter reading is 0.81 ± 0.08 mW.
6.Check that the voltage both ends (TP (+) and TP
7.Press the N key, and set the laser CD read adjustment mode (item number 012).
Remote commander LCD display
012 HrefPw **
8.Check that the laser power meter reading is 0.97 ± 0.10 mW.
9.Check that the voltage both ends (TP (+) and TP
23