Sony service manual V1.100, MZ-N505 SECTION TEST MODE, Outline, Setting Method Of Test Mode

Models: MZ-N505

1 66
Download 66 pages 30.91 Kb
Page 13
Image 13
MZ-N505

MZ-N505

SECTION 4

TEST MODE

OUTLINE

This set provides the Overall adjustment mode that allows CD and MO discs to be automatically adjusted when in the test mode. In this overall adjustment mode, the disc is discriminate between CD and MO, and each adjustment is automatically executed in order. If a fault is found, the system displays its location. Also, the manual mode allows each individual adjustment to be auto- matically adjusted.

Operation in the test mode is performed with the set. A key having no particular description in the text, indicates a set key.

SETTING METHOD OF TEST MODE

There are three different methods to set the test mode:

1Short SL801 (TEST) on the MAIN board with a solder bridge (connect pin <zvn of IC801 to the ground). Then, turn on the power.

– MAIN Board (Conductor Side) –

 

 

 

 

 

C809

 

SL801

 

 

 

 

 

 

SL801

 

 

 

 

 

 

 

 

 

 

 

 

C815

C821

 

C822

 

 

 

 

 

 

 

C625

(TEST)

 

 

+

 

(TEST)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R823

C816

 

 

 

 

 

 

 

 

 

 

 

R822

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R824

R857

 

 

 

96 194 190 186 182 187

189 193

 

 

R821

 

 

 

 

 

C817

 

 

 

98 192 209 184 183 185

191 197 195

 

R858

R825

 

 

 

 

 

 

203 199

 

 

 

 

 

 

 

 

 

 

 

 

17 211 215 207 173 175

180 178

 

R817

C814

FB801

 

 

 

 

 

 

 

04 213 188 181 179 171

176 174

 

R827

 

 

 

 

 

 

C839

 

 

177 169

172 170

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPERATION IN SETTING THE TEST MODE

When the test mode becomes active, first the display check mode is selected.

Other mode can be selected from the display check mode.

When the test mode is set, the LCD repeats the following dis- play.

Set LCD display

All lit

All off

Microcomputer version

display

V1.100

 

When the X key is pressed and hold down, the display at that time is held so that display can be checked.

RELEASING THE TEST MODE

For test mode set with the method 1:

Turn off the power and open the solder bridge on SL801 (TEST) on the MAIN board.

Note: Remove the solders completely. Remaining could be shorted with the chassis, etc.

For test mode set with the method 2 or 3:

Turn off the power.

2In the normal mode, turn on the [HOLD] switch. While press- ing the [VOL --]key press the following order:

>t > t . t . t > t

. t > t . t X t X

3In the normal mode, turn on the [HOLD] switch. While pressing the x key, press the keys on the remote com- mander with the following order:

>t > t . t . t > t . t

>t . t X t X

Note: If electrical adjustment (CD and MO overall adjustment) has not been finished completely, “NV Error” is displayed on LCDs of the set and the remote commander.

13

Page 13
Image 13
Sony V1.100, MZ-N505 SECTION TEST MODE, Outline, Setting Method Of Test Mode, Operation In Setting The Test Mode