Sony MZ-N510CK Adjustment Method of VC1 LOW PB item number, Adjustment Method of VC1 HIGH REC

Models: MZ-N510CK

1 68
Download 68 pages 28.04 Kb
Page 20
Image 20
•Adjustment Method of VC1_LOW (PB) (item number: 741)

MZ-N510CK

Adjustment Method of VC1_LOW (PB) (item number: 741)

Adjustment Method of VC2_LOW (item number: 743)

Set LCD display

Set LCD display

7 41

AD **

**: Adjusted value

 

1.Connect a digital voltmeter to the TP1928 (VCO1) on the MAIN board, and adjust [VOL +]key (voltage up) or [VOL --]key (volt- age down) so that the voltage becomes 2.35 ± 0.05V.

digital voltmeter

MAIN board

TP1928 (VCO1)

TP1311 (GND) •Adjustment Method of VC2_LOW (item number: 743)

7 43

AD **

**: Adjusted value

 

1.Connect a digital voltmeter to the TP1905 (VCOUT) on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL -- ] key (voltage down) so that the voltage becomes 2.30 ± 0.01V.

digital voltmeter

MAIN board

TP1905 (VCOUT)

TP1311 (GND) • Adjustment Method of VC1_HIGH (REC)

2. Press the X key on the set or the

--

key on the remote

2. Press the X key on the set or the

--

key on the remote

commander to write the adjusted value.

commander to write the adjusted value.

Adjustment and Connection Location:MAIN board

Adjustment and Connection Location:MAIN board

 

(see page 24)

 

(see page 24)

• Adjustment Method of VC1_HIGH (REC)

• Adjustment Method of VC2_HIGH

(item number: 742)

(item number: 744)

Set LCD display

Set LCD display

7 42

AD **

**: Adjusted value

 

1.Connect a digital voltmeter to the TP1928 (VCO1) on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL --]key (voltage down) so that the voltage becomes 2.50 ± 0.05V.

digital voltmeter

MAIN board

TP1928 (VCO1)

TP1311 (GND) • Adjustment Method of VC2_HIGH

7 44

AD **

**: Adjusted value

 

1.Connect a digital voltmeter to the TP1905 (VCOUT) on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL -- ] key (voltage down) so that the voltage becomes 2.55 ± 0.01V.

digital voltmeter

MAIN board

TP1905 (VCOUT)

TP1311 (GND) (item number: 742)

2. Press the X key on the set or the

--

key on the remote

2. Press the X key on the set or the

--

key on the remote

commander to write the adjusted value.

commander to write the adjusted value.

Adjustment and Connection Location:MAIN board

Adjustment and Connection Location:MAIN board

 

(see page 24)

 

(see page 24)

20

Page 20
Image 20
Sony MZ-N510CK service manual Adjustment Method of VC1 LOW PB item number, Adjustment Method of VC2 LOW item number