Sony MZ-N510CK service manual Preparation, Pre-check, Rewriting the Patch Data

Models: MZ-N510CK

1 68
Download 68 pages 28.04 Kb
Page 31
Image 31
• Preparation

MZ-N510CK

Rewriting the Patch Data at Replacement of Main Board

This set requires the patch data in the nonvolatile memory (IC852) to be rewritten using the application, when the MAIN board was replaced.

Caution: The application that meets the microcomputer version in this set must be used when rewriting the patch data. Rewriting the patch data using the application not suitable for the microcomputer version could cause the set to malfunction.

For a checking method of the microcomputer version, see “SECTION 4 TEST MODE” (page 13).

• Preparation

1.USB cable (attached to the set)

2.Personal computer in which the Net MD Driver has been installed. (For further information, see “System requirements” (page 4) in

“SECTION 1 SERVICING NOTES”)

3.Application “USB_PatchWriter” for patch data rewriting

How to Get the Application “USB_PatchWriter” for Patch Data Rewriting

Contact our service technical support division to get the application.

Pre-check

1.Check the microcomputer version in this set. (For a checking method of the microcomputer version, see “SECTION 4 TEST MODE” (page 13).)

2.Check that the Net MD Driver has been installed in the personal computer.

3.Make sure that the set is in the Normal mode.

Note: Do not rewrite the patch data in the Test mode.

• Rewriting the Patch Data

1.Connect the set to the personal computer with the USB cable.

2.Start the application “USB_PatchWriter”.

3.Make sure that the following window opens.

4.Click the [USB CONNECT] button.

31

Page 31
Image 31
Sony MZ-N510CK service manual Preparation, Pre-check, Rewriting the Patch Data