•Adjustment Method of CHGV_HIGH (item number: 756)
•Adjustment Method of CHGI_HIGH (Charge current) (item number: 758)
Set LCD display | Set LCD display |
7 56 | AD ** |
**: Adjusted value |
|
Note: Remove the rechargeable battery.
1.Connect a digital voltmeter to the BATT + and BATT – on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL
digital voltmeter
MAIN board
BATT +
BATT –
7 58 | AD ** |
**: Adjusted value |
|
Note: Remove the rechargeable battery.
Connect the resistor (10 ) (0.5%) between terminals of BATT + and BATT
1.Connect a digital voltmeter to the BATT + and BATT – on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL
digital voltmeter
MAIN board
2.Press the X key on the set or the
BATT + BATT –
10 Ω(0.5%)
Adjustment and Connection Location:MAIN board (see page 24)
•Adjustment Method of CHGI_LOW (Charge current) (item number: 757)
Set LCD display
7 57 | AD ** |
|
|
**: Adjusted value |
|
Note: Remove the rechargeable battery.
Connect the resistor (47 ) (0.5%) between terminals of BATT + and BATT
1.Connect a digital voltmeter to the BATT + and BATT – on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL
digital voltmeter
MAIN board
2.Press the X key on the set or the
Adjustment and Connection Location:MAIN board (see page 24)
BATT + BATT –
47 Ω(0.5%)
2.Press the X key on the set or the
Adjustment and Connection Location:MAIN board (see page 24)
23