•Overall CD and MO adjustment items
1. Overall CD adjustment items
Item No. | Description | |
|
| |
312 |
| |
313 | CD electrical offset adjustment | |
314 |
| |
|
| |
321 | CD tracking error gain adjustment | |
|
| |
328 | CD TWPP gain adjustment | |
|
| |
324 | CD tracking error offset adjustment | |
332 | ||
| ||
|
| |
336 | CD ABCD gain adjustment | |
|
| |
344 | CD focus gain adjustment | |
|
| |
345 | CD tracking gain adjustment | |
|
| |
521 | CD | |
522 | ||
| ||
|
|
2. Overall MO adjustment items
Item No. | Description | |
|
| |
112 |
| |
113 | MO electrical offset adjustment | |
114 | ||
| ||
118 |
| |
|
| |
221 | Low reflective CD tracking error gain adjustment | |
|
| |
224 | Low reflective CD tracking error offset adjustment | |
232 | ||
| ||
|
| |
236 | Low reflective CD ABCD level adjustment | |
|
| |
244 | Low reflective CD focus gain adjustment | |
|
| |
245 | Low reflective CD tracking gain adjustment | |
|
| |
121 | MO tracking error gain adjustment | |
|
| |
122 | MO TON offset adjustment | |
|
| |
134 | MO TWPP gain adjustment | |
|
| |
131 | MO double speed read TWPP offset adjustment | |
132 | ||
| ||
|
| |
136 | MO ABCD gain adjustment | |
|
| |
144 | MO focus gain adjustment | |
|
| |
145 | MO tracking gain adjustment | |
|
| |
434 | MO write TWPP gain adjustment | |
|
| |
431 | MO write TWPP offset adjustment | |
|
| |
432 | MO tracking error offset adjustment | |
|
| |
436 | MO write ABCD gain adjustment | |
|
| |
445 | MO write tracking gain adjustment | |
|
| |
411 | MO normal speed read TWPP offset adjustment | |
|
| |
412 | MO tracking error offset adjustment | |
|
| |
448 | 20 sec full recording | |
|
|
5-9. Resume Clear
Perform the Resume clear when all adjustments completed.
• Resume Clear Setting Method
1.Select the manual mode of the test mode, and set item number 043 (see page 13).
This set LCD display
043Resume
2. Press the X key.
This set LCD display
0 43Res
Resume clear complete
043ResClr
3.Press the x key to return to the test mode (display check mode).
When the microcomputer in this set is replaced with a different version of microcomputer, it is needed to initialize the modified program data in the nonvolatile memory and write specific modi- fied data for the new version in the memory.
If the microcomputer is replaced with a different version, the patch data should be rewritten as performed when the nonvolatile memory is replaced.
For a version where the method to write patch data is not described, the modified data should be initialized as specified below:
• Initial set of modified data
1.Select the manual mode of the test mode, and set item number 022 (see page 13).
This set LCD display
022PatClr
2.Press the [ENTER] key and set the address & adjusted value display (see page 14).
This set LCD display
022SCC
CC: Adjusted value
3.Press the X key to initialize the patch data.
(The modified data writing is over, if the adjusted value changes to DD.)
This set LCD display
022SDD
DD: Adjusted value
23