Sony 0 00OfstOK, X Xxmo Run, MZ-R500/R500PC, Overall Adjustment Mode Title Display

Models: R500PC

1 58
Download 58 pages 49.83 Kb
Page 22
Image 22
•Overall Adjustment Mode (Title Display)

MZ-R500/R500PC

Overall Adjustment Mode (Title Display)

This set LCD display

000Assy•Electrical Offset Adjusting Method

0 00OfstOK : (Disc mark) At end power supply adjustment:Outside lit At end of electrical offset adj.:inside lit

Note:On the set having microcomputer version 1.000,the disc mark is displayed on the set LCD only.

:Left side = MO overall adjustment information F : MO overall adjustment completed

1 : Manual adjustment exists(overall adj.not completed)

0 : Not adjusted

Right side = CD overall adjustment information

F : CD overall adjustment completed

1: Manual adjustment exists(overall adj.not completed)

0: Not adjusted

Electrical Offset Adjusting Method

Caution: The electrical offset adjustment must be made with no disc loaded.

1.Make sure that the power supply voltage is 3V.

2.Set the test mode (see page 12).

3.Press the . or [VOL--]key to activate the overall adjustment mode.

This set LCD display

000Assy11

4.Press the [ENTER] key.

This set LCD display

• Adjustment Method of Overall CD and MO Adjustment Mode

1.Setting the test mode (see page 12).

2.Press the . or [VOL --]key activates the overall adjust-

ment mode.

This set LCD display

000AssyX XXMO RUN

3.Insert CD disc in the set, and press the . key to set the Overall CD Adjustment mode. Automatic adjustments are made.

This set LCD display

X XXCD RUN

XXX: Item number for which on adjustment is being executed.

4.In case of CD overall adjustment NG, reset the NV (see page 18), then readjust from the temperature correction (see page 20).

This set LCD display

0 00

NG

Manual background: NG item number

5.If OK through the overall CD adjustments, then perform over- all MO adjustments.

This set LCD display

035OfstManual background

Manual background: Adjusted value

5.Electrical offset adjustment is over, if the following display appears.

This set LCD display

0 00CD OK

6.Insert MO disc in the set, and press the > key to set the Overall MO Adjustment mode. Automatic adjustments are made.

This set LCD display

0 00OfstOK

X XXMO RUN

XXX: Item number for which on

 

adjustment is being executed.

7.In case of MO overall adjustment NG, reset the NV (see page 18), then readjust from the temperature correction (see page 20).

This set LCD display

0 00

NG

Manual background: NG item number

8.If OK through the overall MO adjustments, press the x key to return to the test mode and terminate the Overall Adjustment mode.

This set LCD display

0 00MO OK

22

Page 22
Image 22
Sony 0 00OfstOK, X Xxmo Run, MZ-R500/R500PC, Overall Adjustment Mode Title Display, Electrical Offset Adjusting Method