4.Write specific modified data.
For a version where there is no need for writing specific modi- fied data, the power should be turned off once.
• Modified Data Writing Method (version 1.000)
1.Select the manual mode of the test mode, and set item number 022 (see page 13).
This set LCD display
022PatClr
2.Press the [ENTER] key and set the address & adjusted value display (see page 14).
This set LCD display
022SCC
CC: Adjusted value
3.Press the X key to initialize the patch data.
This set LCD display
022SDD
DD: Adjusted value
4.Select the manual mode of the test mode, and set item number 022 (see page 13).
This set LCD display
023Patch
5.Press the [ENTER] key and set the address & adjusted value display (see page 14).
This set LCD display
023###S00
###: Address
00: Adjusted value
6.Press the [VOL+] key once to change the adjusted value to 01.
7.Press the [T.MARK] + [PAUSE] keys to activate the patch data write mode.
(The following display will appear where 00 is blinking)
This set LCD display
9.Press the X key.
(0D58 is blinking)
This set LCD display
0230D581E
1E: Adjusted value
10.Press the [VOL+] key once to change the blinking portion to
0D59.
This set LCD display
0230D5900
00: Adjusted value
11.Press the x key.
(00 is blinking)
12.Adjust with the [VOL+] key (adjusted value up) or
B2.
This set LCD display
0230D59B2
B2: Adjusted value
13.Press the X key.
(0D59 is blinking)
14.Press the [VOL+] key once to change the blinking portion to
0D5E.
This set LCD display
0230D5E00
00: Adjusted value
15.Press the x key.
(00 is blinking)
16.Adjust with the [VOL+] key (adjusted value up) or
8B.
This set LCD display
0230D5E8B
8B: Adjusted value
17.Press the X key. (0D5E is blinking)
18.Press the [VOL+] key once to change the blinking portion to 0D5F.
This set LCD display
0230D5800
00: Adjusted value
8.Adjust with the [VOL+] key (adjusted value up) or
This set LCD display
0230D581E
1E: Adjusted value
0 230D5F00
00: Adjusted value
19.Press the x key. (00 is blinking)
24