• Modified Data Writing Method (version 1.100)
1.Select the manual mode of the test mode, and set item number 022 (see page 13).
This set LCD display
11.Adjust with the [VOL+] key (adjusted value up) or
AA.
This set LCD display
022PatClr
2.Press the [ENTER] key and set the address & adjusted value display (see page 14).
This set LCD display
0230D5DAA
AA: Adjusted value
12.Press the X key. (0D5D is blinking)
13.Press the [VOL+] key once to change the blinking portion to
0D5E.
This set LCD display
022SCC
CC: Adjusted value
3.Press the X key to initialize the patch data.
This set LCD display
022SDD
DD: Adjusted value
4.Select the manual mode of the test mode, and set item number 023 (see page 13).
This set LCD display
023Patch
5.Press the [ENTER] key and set the address & adjusted value display (see page 14).
This set LCD display
023###S00
###: Address
00: Adjusted value
6.Press the [VOL+] key once to change the adjusted value to 01.
7.Press the [T.MARK] + [PAUSE] keys to activate the patch data write mode.
(The following display will appear where 00 is blinking)
This set LCD display
0230D5C00
00: Adjusted value
8.Press the X key. (0D5C is blinking)
9.Press the [VOL+] key once to change the blinking portion to 0D5D.
This set LCD display
0230D5D00
00: Adjusted value
10.Press the x key. (00 is blinking)
0230D5E00
00: Adjusted value
14.Press the x key.
(00 is blinking)
15.Adjust with the [VOL+] key (adjusted value up) or
This set LCD display
0230D5E04
04: Adjusted value
16.Press the X key. (0D5E is blinking)
17.Press the [VOL+] key to change the blinking portion to 0D61.
This set LCD display
0230D6100
00: Adjusted value
18.Press the x key.
(00 is blinking)
19.Adjust with the [VOL+] key (adjusted value up) or
This set LCD display
0230D6120
20: Adjusted value
20.Press the X key.
(0D61 is blinking)
21.Press the [VOL+] key to change the blinking portion to 0D64.
This set LCD display
0230D6400
00: Adjusted value
22.Press the x key. (00 is blinking)
26