4-10. Sound Skip Check Result Display Mode
This set can display the count of errors that occurred during the recording/playing for checking.
•Setting method of sound skip check result display mode
1.Set the test mode (see page 11).
2.Press the N key or [T.MARK] + N keys, and the playing or recording sound skip result display mode becomes active respectively where the LCD displays the following.
This set LCD display
0 00P | R | ||||||
|
|
|
|
|
|
|
|
Total count of play |
|
|
|
|
| Total count record | |
|
|
|
|
| |||
system errors(hex.) |
|
|
| system errors(hex.) |
3.When the N key is pressed, total error count is displayed on the LCD, and each time the > key is pressed, the display item moves down by one as shown below. Also, if the . key is pressed, the display item moves up by one, then if the [T.MARK] + N keys is pressed, the display in the record mode appears.
When the [T.MARK] + N keys is pressed, total error count is displayed on the LCD, and each time the > key is pressed, the display item moves down by one as shown below. Also, if the . key is pressed, the display item moves up by one, then if the N key is pressed, the display in the play mode appears.
Playing sound skip | Recording sound skip |
result display | result display |
MZ-R501/R501PC
• Cause of Sound Skip Error
| Cause of error | Description of error | |
|
|
| |
| EIB | Sound error correction error | |
|
|
| |
Play | Stat | Decoder status error | |
Adrs | Address access error | ||
| |||
| BEmp | Buffer is empty | |
| BOvr | Buffer is full, and sounds were | |
| dumped | ||
|
| ||
|
|
| |
Record | Bful | Buffer capacity becomes less, | |
| and forcible writing occurred | ||
|
| ||
|
|
| |
| Rtry | Retry times over | |
|
|
|
4.To quit the sound skip check result display mode and to return to the test mode (display check mode), press the x key.
4-11. Key Check Mode
This set can check if the set function normally.
• Setting Method of Key Check Mode
1. Setting the test mode (see page 11).
2. Press the [T.MARK] + X keys activates the key check mode. (At the last two digits, AD value of remote commander key line is displayed in hexadecimal)
This set LCD display
8 88RMC OK
0 00 P R
000 EIB
000 Stat
000 Adrs
000 BEmp
0 00 P R
000 BOvr
000 Bful
000 Rtry
000 ######
3.When each key on the set and on remote commander is pressed, its name is displayed on the LCD. (The operated position is displayed for 4 seconds after the slide switch is operated. If any other key is pressed during this display, the remote com- mander LCD switches to its name display)
Example1: When > key on the set is pressed:
This set LCD display
8 88FF
000 ######
PR :Total play/record errors(hex.)
:Counter of sound skip check each item(hex.)