2.Connect a digital voltmeter to the TP902 (VC) on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL
digital
voltmeter
MAIN board
TP902(VC)
TP910(GND)
3.Press the X key to write the adjusted value.
(The item number changes to 764 when X key is pressed)
Adjustment and Connection Location: MAIN board (see page 20)
•Adjustment method of Vl PWM Duty (item number: 764)
This set LCD display
7 64V1 PWM
1.Press the [ENTER] key and change the LCD display.
This set LCD display
7 64 AD
: Adjusted value
2.Connect a digital voltmeter to the TP901 (VL) on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL
digital
voltmeter
MAIN board
TP901(VL)
TP910(GND)
3.When press the X key to write the adjusted value, LCD dis- plays as follows and power supply manual adjustment has com- pleted.
This set LCD display
MZ-R501/R501PC
3.Adjust with [VOL +], [VOL
(hexadecimal value) becomes the ambient temperature. (Initial value: 14h = 20 ° C, Adjusting range: 80h to 7fh
This set LCD display
014S14
:Address
14: Adjusted value
4. Press the X key to write the adjusted value.
5-7. Laser Power Check
Connection :
laser
power meter
Optical
digital voltmeter
MAIN board
TP(+)
Checking Method :
1.Select the manual mode of test mode (see page 12), and set the laser power adjusting mode (item number 010).
This set LCD display
010Laser
2.Press the . key continuously until the optical
3.Open the cover and set the laser power meter on the objective lens of the optical
4.Press the N key, and set the laser MO read adjustment mode (item number 011).
This set LCD display
0 00ADJ OK
Adjustment and Connection Location: MAIN board
5-6. Temperature Correction
• Adjustment Method of temperature correction
1.Select the manual mode of test mode, and set the mode num- ber 014 (see page 12).
This set LCD display
014SetTmp
2.Measure the ambient temperature.
011LrefPw
5.Press the [ENTER] key and set the address & adjusted value display (See page 13).
This set LCD display
011###S
###: Address
: Adjusted value
6.Check that the laser power meter reading is 0.81 ± 0.08 mW.
7.Check that the voltage both ends (TP (+) and TP
19