23
MZ-R501/R501PC
2. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
S67.
3. Press the Xkey.
4. Set item number 868 (see page 12).
5. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
S01.
6. Press the Xkey.
5-10. Resume Clear
Perform the Resume clear when all adjustments completed.
Resume Clear Setting Method
1. Select the manual mode of the test mode, and set item number
043 (see page 12).
2. Press the Xkey.
3. Press the xkey to return to the test mode (display check
mode).
This set LCD display

0 43 Resume

This set LCD display
0 43 Res 0 43 ResClr
Resume clear complete
This set LCD display

8 67 ***S67

This set LCD display

8 68 ***S20

This set LCD display

8 68 ***S01