MZ-R501/R501PC
8.Press the N key, and set the laser CD read adjustment mode (item number 012).
This set LCD display
012HrefPw
9.Press the [ENTER] key and set the address & adjusted value display (see page 13).
This set LCD display
012###S
###: Address
: Adjusted value
10.Check that the laser power meter reading is 0.97 ± 0.10 mW.
11.Check that the voltage both ends (TP (+) and TP
12.Press the N key, and set the laser MO write adjustment mode (item number 013).
This set LCD display
013WritPw
13.Press the [ENTER] key and set the address & adjusted value display (See page 13).
This set LCD display
013###S
###: Address
: Adjusted value
14.Check that the laser power meter reading is 4.95 ± 0.50 mW.
15.Check that the voltage both ends (TP (+) and TP
16.Press the x key to quit the manual mode, and activate the test mode (display check mode).
Checking and Connection Location: MAIN board
Adjustment/checking and Connection Location:
MAIN BOARD (SIDE B)
5-8. Overall Adjustment Mode
• Configuration of overall adjustment
Overall adjustment mode | . key |
| |
| (Title display) |
|
|
| N key |
|
|
| Protect switch |
|
|
| ON | CD overall | |
|
| adjusting |
|
| All item | NG item exists | |
| OK | or x key | |
|
|
| CD overall |
|
|
| adjustment |
| x key |
| NG |
|
| CD overall |
|
| x key | adjustment | |
| OK |
| |
|
|
| |
| Protect switch | N key | |
| OFF |
|
|
| > key | MO overall | |
|
| adjusting |
|
|
|
| NG item exists |
|
|
| or x key |
|
|
| MO overall |
|
|
| adjustment |
| x key |
| NG |
|
|
| |
|
| MO overall | |
|
| adjustment | |
| x key | OK |
|
ENTER | key |
| Electrical |
|
|
| |
|
|
| offset |
x key |
|
| adjustment |
END SEARCH key |
| Power supply | |
|
|
| |
|
|
| adjustment |
x key |
|
| auto item feed |
Test mode (display check mode)
Note: Adjust the CD first, when performing adjustment.
TP901
(VL)
TP902(VC)
TP910(GND)
R501
TP(+)
20