MZ-R501/R501PC

8.Press the N key, and set the laser CD read adjustment mode (item number 012).

This set LCD display

012HrefPw

9.Press the [ENTER] key and set the address & adjusted value display (see page 13).

This set LCD display

012###S

###: Address

: Adjusted value

10.Check that the laser power meter reading is 0.97 ± 0.10 mW.

11.Check that the voltage both ends (TP (+) and TP (–)) of resis- tor R501 at this time is below 44 mV.

12.Press the N key, and set the laser MO write adjustment mode (item number 013).

This set LCD display

013WritPw

13.Press the [ENTER] key and set the address & adjusted value display (See page 13).

This set LCD display

013###S

###: Address

: Adjusted value

14.Check that the laser power meter reading is 4.95 ± 0.50 mW.

15.Check that the voltage both ends (TP (+) and TP (–)) of resis- tor R501 at this time is below 80 mV.

16.Press the x key to quit the manual mode, and activate the test mode (display check mode).

Checking and Connection Location: MAIN board

Adjustment/checking and Connection Location:

MAIN BOARD (SIDE B)

TP(–)

5-8. Overall Adjustment Mode

• Configuration of overall adjustment

Overall adjustment mode

. key

 

 

(Title display)

 

 

 

N key

 

 

 

Protect switch

 

 

 

ON

CD overall

 

 

adjusting

 

 

All item

NG item exists

 

OK

or x key

 

 

 

CD overall

 

 

 

adjustment

 

x key

 

NG

 

 

CD overall

 

 

x key

adjustment

 

OK

 

 

 

 

 

Protect switch

N key

 

OFF

 

 

 

> key

MO overall

 

 

adjusting

 

 

 

 

NG item exists

 

 

 

or x key

 

 

 

MO overall

 

 

 

adjustment

 

x key

 

NG

 

 

 

 

 

MO overall

 

 

adjustment

 

x key

OK

 

ENTER

key

 

Electrical

 

 

 

 

 

 

offset

x key

 

 

adjustment

END SEARCH key

 

Power supply

 

 

 

 

 

 

adjustment

x key

 

 

auto item feed

Test mode (display check mode)

Note: Adjust the CD first, when performing adjustment.

TP901

(VL)

TP902(VC)

TP910(GND)

R501

TP(+)

20

Page 20
Image 20
Sony R501PC service manual 12HrefPw, 12###S, 13WritPw, 13###S, Configuration of overall adjustment