Camera the Administrating
Alarm: Controls alarm out 1 by synchronizing with an external sensor input or the
Timer: Controls alarm out 1 by the timer. When you select Timer, the Timer mode setting section appears (see page 34).
Alarm mode setting Section
Alarm
Select the alarm to link the alarm out 1 function. If the selected alarm is detected, the alarm out 1 status changes.
Sensor: External sensor connected to sensor input of the camera I/O port
Activity detection: The activity detection function built in the camera.
To set the activity detection function, click Activity detection. The Activity detection setting page appears (see page 40).
Available period
Select the period for which the alarm mode is available. Always: The alarm mode is available any time.
Use scheduler: The alarm mode is available according to the schedule selected on the Schedule No. menu below.
Schedule No.
When Use scheduler is selected on the Available period menu, select the schedule you want the alarm mode being available.
Click to select the check box(es) 1 to 6. You can select multiple schedules.
To check the contents of schedules, click Schedule check. (See “Setting the Schedule — Schedule setting Page” on page 39.)
Alarm durationSelect the duration for which the alarm output is short- circuited between 1 and 60 sec.
Schedule No.
Select the schedule you want to activate the alarm out 1 timer mode.
Click to select the check box(es) 1 to 6. You can select multiple schedules.
The alarm out 1 is
To check the contents of schedules, click Schedule check. (See “Setting the Schedule — Schedule setting Page” on page 39.)
34 Setting the Alarm Out 1 or 2 — Alarm out 1 or 2 setting Page