Camera the Administrating

Capacity warning

Select On to send a warning mail to the Administrator when the built-in memory space is low or the memory is full due to activation of the image memory function.

Select Off if you do not want to send a warning mail. If On is selected, the SMTP server name and Administrator e-mail address menus appear.

SMTP server name

Type the name or IP address of the SMTP server you want to use for sending the E-mail, up to 64 characters.

Administrator e-mail address

Type the E-mail address of the recipient of the warning mail (E-mail address of the Administrator), up to 64 characters.

Mode

Select the mode of the Image memory function.

Manual: Records a still image in the memory manually.

In this mode, when you click the (Trigger) button on the main viewer page, a still image is captured and recorded in the memory. (See “Controlling the Application Manually” on page 12.)

Alarm: Records a still image in the memory by synchronizing with an external sensor input or the built-in activity detection function. When you select Alarm, the Alarm mode setting section appears (see page 36).

Note

If the Suffix menu is set to None, you cannot select the Alarm mode. When you want to use the Alarm mode, set the Suffix menu to Date/Time or Sequence number.

Periodical recording:Records still images in the memory periodically. When you select Periodical recording, the Periodical recording mode setting section appears (see page 37).

Alarm mode setting Section

Alarm

Select the alarm to link the Image memory function. If the selected alarm is detected, a still image is captured and recorded in the selected memory.

Sensor: External sensor connected to sensor input of the camera I/O port

Activity detection: The activity detection function built in the camera.

To set the activity detection function, click Activity detection. The Activity detection setting page appears (see page 40).

Available period

Select the period for which the alarm mode is available. Always: The alarm mode is available any time.

Use scheduler: The alarm mode is available according to the schedule selected in the Schedule No. menu below.

Schedule No.

When Use scheduler is selected on the Available period menu, select the schedule you want the alarm mode being available.

Click to select the check box(es) 1 to 6. You can select multiple schedules.

To check the contents of schedules, click Schedule check. (See “Setting the Schedule — Schedule setting Page” on page 39.)

Alarm buffer configuration

Click Alarm buffer to display the Alarm buffer setting page.

For details, see “Setting the Alarm Buffer — Alarm buffer setting Page” on page 38.

Note

If an alarm occurs during the Alarm buffer processing, that alarm is ignored.

Digest viewer

If you select On, an HTML file (.html) and a Java Script file (.js) are added each time the selected alarm is detected.

When you open the added HTML file using a general browser, the digest viewer runs and you can view the still pictures in the alarm buffer in sequence (quasi- animation).

See “Operating the Digest Viewer” on page 29.

36 Recording Images in Memory — Image memory setting Page