consecutive 2 digits number is added to the Image file name.

Tip

A consecutive number added to Date & time and Sequence number is used to identify each of multiple files created with one alarm event.

Sequence number clear

Click Clear to reset the Sequence number suffix to 1.

Alarm

Select the connected alarm.

Sensor input: The external sensor which is connected to the sensor input of the camera I/O port.

Motion detection: Click Motion detection button, and the Motion detection setting page is displayed. You can set the motion detection function (page 52).

Note

Motion detection works only when the Video mode is set to MPEG4 and the Cropping is set to Off.

Effective period

Set the period when the alarm detection is effective. Always: The alarm detection is always effective. Schedule: You can specify the period when the alarm

detection is effective in the schedule setting in the other section.

Click Schedule and the setting menu for the effective period is displayed. (“Setting the Schedule — Schedule setting Menu” on page 50)

Alarm buffer

Select Use alarm buffer when you forward the image/ audio of before and after the alarm detection (pre-alarm, post-alarm).

If you do not select it, only the image of the moment of the alarm detection is forwarded.

Click Alarm buffer to display the Alarm buffer setting menu.

For details, see “Setting the Alarm Buffer — Alarm buffer setting Menu” on page 51.

OK/Cancel

See “Buttons common to every setting menu” on page 24.

Periodical recording Tab — Setting the Periodical recording mode

You can set to record the image file to the built-in memory periodically.

Periodical recording

Select On when you want to use periodical recording. If you select Off, the Periodical recording is not executed.

Image file name

Type the file name of the image recorded to the built-in memory up to 10 alphanumeric, - (hyphen) and _ (under score).

Note

You cannot send the audio file by using the periodical recording function.

Suffix

Select a suffix to add to the file name.

None: The recording file name will be the Image file name.

Date & time: The date & time suffix is added to the Image file name.

The date/time suffix consists of lower two-digits of year (2 digits), month (2 digits), date (2 digits), hour (2 digits), minute (2 digits), second (2 digits), and consecutive number (2 digits), thus 14-digit number is added to the file name.

Sequence number: A consecutive number of 10 digits between 0000000001 and 4294967295 and two fixed digits 00 is added to the Image file name.

Sequence number clear

Click Clear and the suffix of the sequence number returns to 1.

Camera the Administrating

Recording Images in Memory — Image memory setting Menu

45